d indicates emergency stop activated when any of digital inputs DI1~DI6 signal is set to Emergency Stop (EMGS). The manual's first action is: “If it does not need to use "Emergency Stop (EMGS)" as input signal, the users only need to confirm that if all of the digital inputs DI1~DI6 are not set to "Emergency Stop (EMGS)". (The setting value of parameter P2-10 to P2-15 is not set to 21.)”
- Model
- Delta ASDA-B series
- Display shows
- Emergency stop activated (d)
- Type
- Error code
- Source
- Manual p. 97
What d means
Emergency stop activated p. 97
Common causes
- Please check if any of digital inputs DI1~DI6 signal is set to "Emergency Stop (EMGS)". p. 97
What to do
- If it does not need to use "Emergency Stop (EMGS)" as input signal, the users only need to confirm that if all of the digital inputs DI1~DI6 are not set to "Emergency Stop (EMGS)". (The setting value of parameter P2-10 to P2-15 is not set to 21.) p. 97
- If it is necessary to use "Emergency Stop (EMGS)" as input signal, the users only need to confirm that which of digital inputs DI1~DI6 is set to "Emergency Stop (EMGS)" and check if the digital input signal is ON (It should be activated). p. 97
Before you service the product, read the safety instructions in the manual p. 3.
If d is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about d; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.