E indicates a reverse limit switch error when any of digital inputs DI1~DI6 signal is set to Reverse inhibit limit (CWL) and the signal is ON. The manual's first action is: “If it does not need to use "Reverse inhibit limit (CWL)" as input signal, the users only need to confirm that if all of the digital inputs DI1~DI6 are not set to "Reverse inhibit limit (CWL)". (The setting value of parameter P2-10 to P2-15 is not set to 22.)”
- Model
- Delta ASDA-B series
- Display shows
- Reverse limit switch error (E)
- Type
- Error code
- Source
- Manual p. 97
What E means
Reverse limit switch error p. 97
Common causes
- Please check if any of digital inputs DI1~DI6 signal is set to "Reverse inhibit limit (CWL)" and check if the signal is ON or not. p. 97
What to do
- If it does not need to use "Reverse inhibit limit (CWL)" as input signal, the users only need to confirm that if all of the digital inputs DI1~DI6 are not set to "Reverse inhibit limit (CWL)". (The setting value of parameter P2-10 to P2-15 is not set to 22.) p. 97
- If it is necessary to use "Reverse inhibit limit (CWL)" as input signal, the users only need to confirm that which of digital inputs DI1~DI6 is set to "Reverse inhibit limit (CWL)" and check if the digital input signal is ON (It should be activated). p. 97
Before you service the product, read the safety instructions in the manual p. 3.
If E is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.