MOTOR TEMPERATURE (0x4310) means the estimated motor temperature rise exceeded the defined alarm limit. The manual's first action is: “Check the motor's rated parameters and load condition. Allow the motor to cool. Ensure the motor cooling system is functioning properly: inspect the cooling fan, clean cooling surfaces, etc. Check the motor thermal model settings (parameters 31.09…31.14).”
- Model
- ABB ACS850
- Display shows
- MOTOR TEMPERATURE (0x4310) (2005)
- Type
- Alarm code
- Source
- Manual p. 283
What 2005 means
MOTOR TEMPERATURE (0x4310) p. 283
Common causes
- The estimated motor temperature rise (based on the motor thermal model) exceeds the alarm limit defined by parameter 31.03 Mot temp1 almLim (Motor temperature 1 alarm limit). p. 283
What to do
- Check the motor's rated parameters and load condition. Allow the motor to cool. Ensure the motor cooling system is functioning properly: inspect the cooling fan, clean cooling surfaces, etc. Check the motor thermal model settings (parameters 31.09…31.14). p. 283
Before you service the product, read the safety instructions in the manual p. 179.
If 2005 is still not resolved
- 请联系当地的 ABB 代表 p. 296 “请联系当地的 ABB 代表”
This page summarises what the manufacturer’s manual says about 2005; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.