ABB ACS850 Error 2001: BRAKE NOT CLOSED (0x7186)

ABB ACS850 · taken from the manufacturer’s manual, pages cited

Alarm code2001

BRAKE NOT CLOSED (0x7186) means the brake confirmation signal did not reach the expected state during closing. The manual's first action is: “Check the mechanical brake connections. Check the mechanical brake settings, parameter group 42 Mech brake ctrl. Determine whether the issue is with the confirmation signal or the brake itself; verify whether the brake is closed or open.”

Model
ABB ACS850
Display shows
BRAKE NOT CLOSED (0x7186) (2001)
Type
Alarm code
Source
Manual p. 283

What 2001 means

BRAKE NOT CLOSED (0x7186) p. 283

Common causes

  • Mechanical brake control alarm. The alarm is activated if the brake confirmation does not reach the expected state during brake closing. p. 283

What to do

  1. Check the mechanical brake connections. Check the mechanical brake settings, parameter group 42 Mech brake ctrl. Determine whether the issue is with the confirmation signal or the brake itself; verify whether the brake is closed or open. p. 283

Before you service the product, read the safety instructions in the manual p. 179.

If 2001 is still not resolved

  • 请联系当地的 ABB 代表 p. 296
    “请联系当地的 ABB 代表”

This page summarises what the manufacturer’s manual says about 2001; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.