ABB ACS850 Error 2000: BRAKE START TORQUE (0x7185)

ABB ACS850 · taken from the manufacturer’s manual, pages cited

Alarm code2000

BRAKE START TORQUE (0x7185) means the motor start torque did not reach the required level. The manual's first action is: “Check the brake open torque setting, parameter 42.08. Check the inverter torque and current limits. See parameter group 20 Limits.”

Model
ABB ACS850
Display shows
BRAKE START TORQUE (0x7185) (2000)
Type
Alarm code
Source
Manual p. 283

What 2000 means

BRAKE START TORQUE (0x7185) p. 283

Common causes

  • Mechanical brake alarm. The alarm is activated if the required motor start torque (parameter 42.08 Brake open torq) is not reached. p. 283

What to do

  1. Check the brake open torque setting, parameter 42.08. Check the inverter torque and current limits. See parameter group 20 Limits. p. 283

Before you service the product, read the safety instructions in the manual p. 179.

If 2000 is still not resolved

  • 请联系当地的 ABB 代表 p. 296
    “请联系当地的 ABB 代表”