Code 0011 indicates brake chopper IGBT temperature has exceeded the internal fault limit. The manual's first action is: “Allow the chopper to cool down. Check that the ambient temperature is not excessive. Verify that the cooling fan is functioning. Ensure there is no obstruction to airflow. Check cabinet size and cooling performance. Review the brake resistor overload protection settings (parameters 48.01‑48.05). Verify that the brake cycle meets the allowed limits. Check that the inverter’s AC supply voltage is within the permitted range.”
- Model
- ABB ACS850
- Display shows
- BC OVERHEAT (0x7181) (0011)
- Type
- Fault code
- Source
- Manual p. 290
What 0011 means
BC OVERHEAT (0x7181) p. 290
Common causes
- Brake chopper IGBT temperature has exceeded the internal fault limit. p. 290
What to do
- Allow the chopper to cool down. Check that the ambient temperature is not excessive. Verify that the cooling fan is functioning. Ensure there is no obstruction to airflow. Check cabinet size and cooling performance. Review the brake resistor overload protection settings (parameters 48.01‑48.05). Verify that the brake cycle meets the allowed limits. Check that the inverter’s AC supply voltage is within the permitted range. p. 290
Before you service the product, read the safety instructions in the manual p. 179.
If 0011 is still not resolved
- 请联系当地的 ABB 代表 p. 296 “请联系当地的 ABB 代表”
This page summarises what the manufacturer’s manual says about 0011; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.