Drive heatsink is hot. This alarm warns that a DEVICE OVERTEMP fault may be near. The manual's first action is: “Check for and correct: • Fan failure. • Obstructions in the air flow. • Dirt or dust coating on the heat sink. • Excessive ambient temperature. • Excessive motor load.”
- Model
- ABB ACS550-01 / ACS550-U1
- Display shows
- DEVICE OVERTEMP (2009)
- Type
- Alarm code
- Source
- Manual p. 268
What 2009 means
DEVICE OVERTEMP p. 268
Common causes
- Drive heatsink is hot. This alarm warns that a DEVICE OVERTEMP fault may be near. p. 268
What to do
- Check for and correct: • Fan failure. • Obstructions in the air flow. • Dirt or dust coating on the heat sink. • Excessive ambient temperature. • Excessive motor load. p. 268
Before you service the product, read the safety instructions in the manual p. 6.
If 2009 is still not resolved
- contact your local ABB representative for replacement p. 6 “Never attempt to repair a malfunctioning drive; contact your local ABB representative for replacement.”
- For more technical information, contact your local ABB representative. p. 7 “For more technical information, contact your local ABB representative.”
This page summarises what the manufacturer’s manual says about 2009; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.