ABB ACS550-01 / ACS550-U1 Error 2008: PANEL LOSS

ACS550-01/U1 drive · taken from the manufacturer’s manual, pages cited

Fault code2008

Panel communication is lost and either: drive is in local control mode (the control panel displays LOC), or drive is in remote control mode (REM) and is parameterized to accept start/stop, direction. The manual's first action is: “To correct check: • Communication lines and connections. • Parameter 3002 PANEL COMM ERR. • Parameters in Group 10: START/STOP/DIR and Group 11: REFERENCE SELECT (if drive operation is REM).”

Model
ABB ACS550-01 / ACS550-U1
Display shows
PANEL LOSS (2008)
Type
Fault code
Source
Manual p. 267

What 2008 means

PANEL LOSS p. 267

Common causes

  • Panel communication is lost and either: • Drive is in local control mode (the control panel displays LOC), or • Drive is in remote control mode (REM) and is parameterized to accept start/stop, direction or reference from the control panel. p. 267

What to do

  1. To correct check: • Communication lines and connections. • Parameter 3002 PANEL COMM ERR. • Parameters in Group 10: START/STOP/DIR and Group 11: REFERENCE SELECT (if drive operation is REM). p. 267

Before you service the product, read the safety instructions in the manual p. 6.

If 2008 is still not resolved

  • contact your local ABB representative for replacement p. 6
    “Never attempt to repair a malfunctioning drive; contact your local ABB representative for replacement.”
  • For more technical information, contact your local ABB representative. p. 7
    “For more technical information, contact your local ABB representative.”