ABB ACS150 Error A2009: DEVICE OVERTEMP

ABB ACS150 · taken from the manufacturer’s manual, pages cited

Fault codeA2009

A2009 DEVICE OVERTEMP means the drive IGBT temperature is excessive, with an alarm limit of 120 °C. The manual's first action is: “Check ambient conditions. See also section Derating on page 138.”

Model
ABB ACS150
Display shows
DEVICE OVERTEMP (A2009)
Type
Fault code
Source
Manual p. 128

What A2009 means

DEVICE OVERTEMP p. 128

Common causes

  • Drive IGBT temperature is excessive. Alarm limit is 120 °C. p. 128

What to do

  1. Check ambient conditions. See also section Derating on page 138. p. 128
  2. Check air flow and fan operation. p. 128
  3. Check motor power against drive power. p. 128

Before you service the product, read the safety instructions in the manual p. 149.

If A2009 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact ABB service.

This page summarises what the manufacturer’s manual says about A2009; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.