A2009 DEVICE OVERTEMP means the drive IGBT temperature is excessive, with an alarm limit of 120 °C. The manual's first action is: “Check ambient conditions. See also section Derating on page 138.”
- Model
- ABB ACS150
- Display shows
- DEVICE OVERTEMP (A2009)
- Type
- Fault code
- Source
- Manual p. 128
What A2009 means
DEVICE OVERTEMP p. 128
Common causes
- Drive IGBT temperature is excessive. Alarm limit is 120 °C. p. 128
What to do
- Check ambient conditions. See also section Derating on page 138. p. 128
- Check air flow and fan operation. p. 128
- Check motor power against drive power. p. 128
Before you service the product, read the safety instructions in the manual p. 149.
If A2009 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact ABB service.