ABB ACS 160 Error 25: MOT OVER TEMP

Low voltage AC drive · taken from the manufacturer’s manual, pages cited

Fault code25

The MOT OVER TEMP code indicates a motor overtemperature alarm or fault exists. The manual's first action is: “Relay is energised.”

Model
ABB ACS 160
Display shows
MOT OVER TEMP (25)
Type
Fault code
Source
Manual p. 77

What 25 means

MOT OVER TEMP p. 77

Common causes

  • Motor overtemperature alarm or fault exists. p. 77
  • Reserved. p. 77

What to do

  1. Relay is energised. p. 77

Before you service the product, read the safety instructions in the manual p. 88.

If 25 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact ABB service.

This page summarises what the manufacturer’s manual says about 25; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.