  • Agilent Italian version - Remote Advisor Reports - Included in Agilent Advantage Bronze Support Agreements - Technical Overview Manual

    This document describes the features and technical characteristics of the Remote Advisor reports included in the Agilent Advantage Bronze contracts, as well as how these reports help users make decisions to improve the effectiveness of their instruments.

  • Agilent Italian version- Cary 60 UV-Vis Specifications Manual

    The Agilent Cary 60 is a UV-Vis spectrophotometer produced by Agilent. It uses a classic Cary optical design with a Czerny-Turner monochromator. The spectral range is 190-1100nm, the resolution is less than 1.5nm, and a single xenon light source is used with a lifetime of up to 10 years. It has two silicon detectors, multiple layers of quartz optical elements, a scanning speed of up to 24000nm/min, a maximum speed of 80 points/second for time events, and a grid shift in non-measurement. It is immune to external scattered light and is fully controlled by a PC via Windows and a USB port. It has GLP and CFR 21 Part 11 software for complete instrument validation in accordance with all pharmacopoeias.

  • Agilent Italian version - Consumables Supplies Required for Repair Manual

    When your system needs repairs, it’s best to have complete coverage that includes a supply of the spare parts and consumables not covered by basic repair services. That’s why the Agilent Advantage Bronze, Silver and Gold services include the Optional Repair Parts and Consumables. The Optional Repair Parts and Consumables option covers the cost of all replacement parts or consumables needed by the technician to diagnose issues and repair your systems. Since all “Advantage” services also cover travel costs, labor and parts, you can be confident that you’re covered for all your repair costs. You’ll get all original Agilent parts and consumables regardless of the number of repairs or the quantity of products required to return your system to normal operation. Even if you only have one repair, services that include all the spare parts and consumables will easily pay for the difference in price over services that don’t.

  • Agilent Guida alla scelta delle colonne Zorbax Agilent per HPLC Manual

    This document mainly introduces the ZORBAX series products, including ZORBAX StableBond, ZORBAX SB-Aq, ZORBAX Rx, ZORBAX Eclipse XDB, ZORBAX Bonus-RP, ZORBAX Extend-C18, other ZORBAX HPLC analytical columns and ZORBAX CombiHT, ZORBAX Rapid Resolution 3.5 µm, MicroBore and Capillary.

  • Agilent Italian Version - Agilent 7890A Network Gas Chromatograph Data Sheet Manual

    The Agilent 7890A Gas Chromatograph is a state-of-the-art gas chromatograph with excellent performance for any application. The outstanding performance is guaranteed by advanced Electronic Pneumatic Control (EPC) modules and extremely precise control of the GC oven temperature. Each EPC unit is optimized for its intended use and equipped with specific injector and detector. The temperature control of the 7890A GC oven allows for fast and precise gradients. The overall thermal performance ensures optimal chromatography with peak symmetry, retention time repeatability, and retention index accuracy. Agilent's Capillary Flow Technology provides a new dimension to chromatography, ensuring reliable and leak-free capillary connections in the oven that can withstand repeated cycles. The 7890A GC features enhanced firmware to expand the capabilities of the innovative capillary flow modules and advanced software to simplify backflush setup and operation. In addition to facilitating the analysis of complex matrices, it offers increased flexibility and reliability.

  • Agilent Pursuit XRs Prep LC column Italian Manual

    Pursuit® XRs Prep HPLC Columns are a new type of LC prep column developed by Varian. They are made of high-purity silica gel and have extremely high separation ability, suitable for the separation and purification of various complex samples.

  • Agilent VF-5ht UltiMetal Italian Manual

    The VF-5ht UltiMetal is the latest addition to Varian’s popular FactorFour™ series of ultra-low bleed GC columns. FactorFour columns are premium-quality GC columns that offer purge specifications up to four times lower than those of other products on the market. The columns are produced using an exclusive and patented stabilization technology that guarantees maximum signal-to-noise ratio for trace analysis, minimum detector contamination, greater mass spectrum integrity, minimal ion background and faster stabilization. In short, they provide significantly improved chromatographic performance.

  • Agilent Italian version-On Demand Repair Services Update trail-5980-2796ITIT Manual

    This article introduces Agilent Technologies' on-site repair services, including repair costs, repair process and repair scope.

  • Agilent OQ/PV Software per ChemStation Agilent Manual

    This document describes the OQ/PV services for Agilent ChemStation software, including safety, communication, and internal testing. These services use a written protocol and software qualification procedure to ensure that Agilent ChemStation operates within pre-defined limits, can handle any safety issues, and reports chromatograph results accurately. These services are also available for systems configured solely for data analysis, such as Agilent networked solutions. All tests are fully documented. The documentation attests to the software's compliance with test specifications and can be used as support for FDA 21 CFR Part II certification.

  • Agilent OQ/PV per LC HP 1090 Manual

    This document contains the operation and maintenance instructions provided by Agilent Technologies for Hewlett-Packard 1090 Series liquid chromatographs.

  • Agilent OQ/PV cromatografo liquido Agilent Serie 1100 Manual

    This document describes Agilent Technologies' OQ/PV procedures for the Agilent 1100 Series Liquid Chromatograph

  • Agilent OQ/PV per LC Serie HP 1050 Manual

    This file describes the performance validation and operational qualification procedures for the Hewlett-Packard 1050 Liquid Chromatograph

  • Agilent OQ/PV per gascromatografo Serie HP 5890 Manual

  • Agilent OQ/PV per GC Agilent 6850 Manual

    This document is Agilent Technologies' 6850 GC OQ/PV procedure, which describes how to evaluate the instrument performance and verify if it meets the specification.

  • Agilent OQ/PV per GC Agilent Serie 6890 Manual

    This file introduces OQ/PV test methods for Agilent 6890 series gas chromatographs