WITec alpha300+ Manuals

ManualLib has 2 documents for the WITec alpha300+ (microscope): 1 user manual, 1 product leaflet. Every file can be read online or downloaded as a PDF for free.

User Manual 1Product Leaflet 1

Key facts

Brand
WITec
Model
alpha300+
Category
microscope
Documents
2
Languages
EN
Last added
2026-10-05

Start here

WITec Alpha300/Alpha500/Alpha700 AFM Contact Mode User Manual

WITec Alpha300/Alpha500/Alpha700 AFM Contact Mode User Manual

User Manual 18 pages · 2.1 MB · EN

This manual explains the principles of atomic force microscopy (AFM) in contact mode and provides detailed instructions for configuring the WITec Control software. It covers beam‑path alignment, cantilever selection, and the software interface used for AFM contact measurements.

The document guides users through the adjustment and alignment procedures, describes the speed‑button functions, control window layout, and data acquisition sequencers (Image Scan, Line Scan, Distance Curve), and includes recommended parameter settings for successful measurements.

Read online

WITec alpha300+ specifications

Cantilever length100–200 µm
Tip size<10 nm
Recommended cantilever spring constant<1 N/m
Proportional gain (recommended)5.0
Integral gain (recommended)5.0
Typical image scan points per line256–512
Typical image scan lines per image256–512
Typical image scan width/height2–30 µm
Typical time per line0.5–2 s

Source: WITec Alpha300/Alpha500/Alpha700 AFM Contact Mode User Manual

All WITec alpha300+ documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What cantilever spring constant should be used for AFM contact mode?

Cantilevers with spring constants below 1 N/m are recommended for contact‑mode measurements.

From: WITec Alpha300/Alpha500/Alpha700 AFM Contact Mode User Manual

How can I start an automatic tip approach in the WITec software?

Press the Auto‑Approach speed button or select the Start Approach button from the Microscope Z Control menu.

From: WITec Alpha300/Alpha500/Alpha700 AFM Contact Mode User Manual

What excitation wavelengths does the alpha300+ support?

The system is configured for 532 nm and 785 nm excitation wavelengths, with highest sensitivity at both.

From: WITec alpha300+ Confocal Raman Microscope System

What is the maximum Raman mapping area of the alpha300+?

Large-area Raman mapping is possible up to 25 x 25 mm.

From: WITec alpha300+ Confocal Raman Microscope System