WITec alpha300+ Confocal Raman Microscope System

The WITec Confocal Raman Microscope System alpha300+ is a high-sensitivity, high-throughput confocal Raman microscopy system for 532 and 785 nm excitation wavelengths. The system features:


WITec alpha300+ Confocal Raman Microscope System - cover page
Brand
WITec
Category
microscope
Document type
Product Leaflet
Language
English
Pages
3
File format
PDF
File size
90 KB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
EA396B0E24F6D933076586815C5B4F49

About this manual

The WITec alpha300+ is a confocal Raman microscope system offered with micro-Raman mapping functionality and highest sensitivity for 532 nm and 785 nm excitation wavelengths. The document lists the system's configuration and specifications, including the alpha300 M base microscope, motorized x-y sample stage, alphaControl digital controller, Raman laser coupler, Raman filter sets, UHTS 300 spectrometers, CCD cameras, laser modules and Zeiss objectives.

The system provides confocal microscopy in reflection, confocal fluorescence and large-area Raman mapping up to 25 x 25 mm, with automated sample positioning in x-, y- and z-direction. It is operated through the WITec Control FOUR software package, which handles all measurement modes, TrueScan position control and automated multi-area measurements and time series.

What's inside

  • Confocal Raman Mapping Functionality
  • Confocal Microscopy and Fluorescence
  • Motorized Sample Positioning
  • alphaControl Digital Controller
  • Raman Laser Coupler and Filter Sets
  • UHTS 300 Spectrometer
  • CCD Camera
  • WITec Control FOUR Software
  • Laser Modules
  • Microscope Objectives

Specifications

Excitation Wavelengths532 nm and 785 nm
Raman Mapping AreaUp to 25 x 25 mm
Laser Focus SizeDiffraction limited lateral, typ. 250 nm at 532 nm with objective NA 1.4
Sample SizeMax. 120 mm in x- and y-direction, 25 mm in height
Detection Wavelength RangeVIS, typ. from < 95 to ca. 4000 wavenumbers at 532 nm excitation
Sample Stage25 x 25 mm travel range, 100 nm step size, reproducibility < 1 µm
VIS SpectrometerUHTS 300, f/4 300mm focal length, triple grating turret with 1800 and 600 lines/mm at 500nm
CCD Camera (VIS)ANDOR iDus DV401A-BV-352, Peltier cooling down to -65°C at 20°C room temperature
532 nm LaserCoherent Compass Sapphire, 75 mW at laser output, Laser Class 3B
785 nm LaserTOPTICA Diode Laser Module SYS XTRA 785, 300 mW power
ControlleralphaControl digital controller with 80MHz FPGA, 64MB SDRAM, 4 MB SRAM, USB 3.0
ObjectivesZeiss 10x EC Epiplan DIC (NA 0.2), 50x LD Epiplan-Neofluar DIC (NA 0.55) and 100x EC Epiplan-Neofluar (NA 0.90)

Frequently asked questions

What excitation wavelengths does the alpha300+ support?

The system is configured for 532 nm and 785 nm excitation wavelengths, with highest sensitivity at both.

What is the maximum Raman mapping area of the alpha300+?

Large-area Raman mapping is possible up to 25 x 25 mm.

What software is included with the WITec alpha300+?

The system is delivered with the WITec Control FOUR License, which includes free upgrades for 2 years and controls all measurement modes in one software package.

How is the CCD camera cooled?

The CCD cameras are thermoelectrically (Peltier) cooled down to about -65°C at 20°C room temperature.