Novatech Controls HBC-4301A Hot Bonding Controller Operators Manual
The document is the Operators Manual for the Novatech Controls HBC-4301A Hot Bonding Controller. It details the procedures for getting started, including hardware connections and software installation. The guide explains how to configure thermocouples and zones, create temperature cycles, and manage vacuum pumps via the control case and PC software.
Read onlineNovatech Controls HBC-4301A specifications
| Number of T/C Inputs | 16 (expandable to 32 using two control cases) |
|---|---|
| Thermocouple Type | Type K or J |
| Temperature Range | Up to 300°C (570°F) |
| Accuracy | +/- 1°C |
| Number of Heater Zones | 3 (expandable to 6 zones using two control cases) |
| Heater Power (240VAC) | 7.2kW total (2.4kW per zone) |
| Heater Power (110VAC) | 3.3kW total (1.1kW per zone) |
| Vacuum Sources | 2 Air operated ejectors |
| Operating Temperature | -25°C to 55°C |
| Degree of Protection | IP65 with the case closed |
Source: Novatech Controls HBC-4301A Hot Bonding Controller Operator's Manual
All Novatech Controls HBC-4301A documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
What thermocouple types are supported by the HBC-4301A?
The controller supports Type K or J thermocouples.
From: Novatech Controls HBC-4301A Hot Bonding Controller Operator's Manual
Can the number of heater zones be expanded?
Yes, the standard is 3 zones, but it can be expanded to 6 zones using two control cases.
From: Novatech Controls HBC-4301A Hot Bonding Controller Operator's Manual
What are the default operator name and password?
If starting the program for the first time, the Operator name will be 'Default' and the password will be 'password'.
From: Novatech Controls HBC-4301A Hot Bonding Controller Operators Manual
How do you start a heat cycle immediately?
Select the cycle and press 'S' to go to the Immediate / Auto window, then press the Enter key to start the cycle.
From: Novatech Controls HBC-4301A Hot Bonding Controller Operators Manual
How often should the HBC-4301A be calibrated?
The manufacturer recommends calibration every 12 months.
From: Novatech Controls HBC-4301A Hot Bonding Controller Calibration Manual
What equipment is required for calibration?
Required equipment includes an RTD sensor Class A, thermocouple output generator, digital multimeter, 4-20mA loop powered device, vacuum measuring instrument, and pressurised air supply.
From: Novatech Controls HBC-4301A Hot Bonding Controller Calibration Manual