Key facts
- Brand
- Nellcor
- Model
- PM100N
- Category
- Professional medical equipment
- Industry
- Health
- Documents
- 2
- Languages
- EN · ZH
- Last added
- 2026-11-13
Start here

Nellcor PM100N Bedside SpO2 Patient Monitoring System Home User Guide
The Nellcor PM100N is a prescription device designed for home use to monitor a patient's SpO2 (blood oxygen saturation) and pulse rate. This guide is intended for family caregivers or patients who have been prescribed the system by a clinical doctor. It details how to prepare the unit, attach sensors, interpret readings on the main screen, and respond to various alarms. This manual is written in Chinese.
Read onlineNellcor PM100N specifications
| SpO2 measurement range | 1% to 100% |
|---|---|
| Pulse rate measurement range | 20 to 250 bpm |
| Pulse amplitude measurement range | 0.03% to 20% |
| SpO2 accuracy (adult, 70% to 100%) | ±2 digits |
| SpO2 accuracy (adult and neonate low saturation, 60% to 80%) | ±3 digits |
| SpO2 accuracy (neonate, 70% to 100%) | ±2 digits |
| SpO2 accuracy (low perfusion, 70% to 100%) | ±2 digits |
| SpO2 accuracy (adult and neonate with motion, 70% to 100%) | ±4 digits |
| Pulse rate accuracy (adult and neonate, 20 to 250 bpm) | ±3 digits |
| Pulse rate accuracy (low perfusion, 20 to 250 bpm) | ±3 digits |
| Pulse rate accuracy (adult and neonate with motion, 20 to 250 bpm) | ±5 digits |
| Power requirements | 100 to 240 VAC, 50/60 Hz, 45 VA |
| Fuse rating | Fast-acting 2 A 32VAC/DC, Fast-acting 500 mA 32VAC/50DC |
| Battery type | Lithium ion |
| Battery capacity | Minimum of five hours using new, fully charged battery with no alarms; optional 10-hour battery |
| Operating temperature | 5 °C to 40 °C (41 °F to 104 °F) |
| Transport/storage temperature | -20 °C to 60 °C (-4 °F to 140 °F) |
| Operating humidity | 15% to 93% noncondensing |
| Operating altitude | -170 m to 4877 m (-557 ft to 16,000 ft) |
| Weight | 1.5 kg (3 lbs) |
| Size | 82 H x 255 W x 155 D (mm), (3.23 H x 10.04 W x 6.10 D (in)) |
| Available modes | Standard, Homecare, and Sleep Study |
| Connectivity | Wired and USB trend data export; nurse call capability |
Source: Nellcor PM100N Bedside SpO2 Patient Monitoring System Product Leaflet
All Nellcor PM100N documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the SpO2 measurement range of the PM100N?
The SpO2 measurement range is 1% to 100%.
From: Nellcor PM100N Bedside SpO2 Patient Monitoring System Product Leaflet
What is the pulse rate measurement range?
The pulse rate measurement range is 20 to 250 beats per minute.
From: Nellcor PM100N Bedside SpO2 Patient Monitoring System Product Leaflet
What is the purpose of the Nellcor PM100N monitoring system?
The system measures a patient's pulse rate and blood oxygen levels, alerting users if values fall outside preset limits.
From: Nellcor PM100N Bedside SpO2 Patient Monitoring System Home User Guide
Who is responsible for prescribing the monitoring system?
A clinical doctor determines whether you can take the system with you and prescribes the appropriate sensors based on the patient's size and age.
From: Nellcor PM100N Bedside SpO2 Patient Monitoring System Home User Guide