Key facts
- Brand
- moxa
- Model
- EDS-308
- Documents
- 2
- Languages
- EN
- Last added
- 2023-10-19
Start here

Moxa EDS-308/309 Series Quick Installation Guide
This guide provides step-by-step instructions for installing and configuring the Moxa EtherDevice™ EDS-308/309 Series smart Ethernet switches. These switches offer industrial reliability with features like dual DC power inputs, wide operating temperature range, and built-in smart alarm functions. They are designed for mounting on DIN-rail or walls and support both 10/100BaseT(X) and 100BaseFX ports. The guide covers mounting, wiring, DIP switch settings, and LED indicators for proper operation.
Safety warnings and compliance details are included, such as ATEX certification for hazardous environments and requirements for SELV power supply. The guide also explains how to connect alarm contacts for fault monitoring and how to configure port alarms using DIP switches.
Moxa EDS-308 specifications
| Operating Temperature | -40 to 75°C |
|---|---|
| Port Types | 10/100BaseT(X) and 100BaseFX |
| Switching Technology | Store and Forward |
| Power Inputs | Redundant dual DC power inputs |
| IP Rating | IP30 |
All Moxa EDS-308 documents by type
The shortest path to a working setup, usually only a few pages.
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What is the operating temperature range for the EDS-308/309?
The operating temperature range is -40 to 75°C for “-T” models, or 0 to 60°C for standard models.
How do I mount the EDS-308/309?
You can mount it on DIN-rail or on a wall using wall mounting plates and screws.
What is the operating temperature range for the EDS-308/309?
The standard operating temperature range is 0 to 60°C, with -40 to 75°C available for -T models.
What power supply is required for the EDS-308/309?
The switches require a 12 to 48 VDC power supply with redundant inputs, rated at 1.1A minimum.