This manual provides installation and start-up instructions for the Motortronics ME2 Series Micro AC Drive. It covers general information, specifications, and mounting dimensions for the drive unit. The document details power and control wiring practices, including terminal block locations and recommended wire sizes for various models.
Read onlineMotortronics ME2 Series specifications
| Input Voltage (Single Phase) | 110 ~ 120V (-15% ±10%) |
|---|---|
| Input Voltage (Single Phase) | 200 ~ 240V (+10%/-15%) |
| Input Voltage (Three Phase) | 380 ~ 460V |
| Control Method | Sinusoidal wave PWM control |
| Frequency Range | 4 ~ 16 kHz |
| Frequency Resolution (Digital) | 0.1 Hz (0-99.9Hz) |
| Overload Capacity | 150% for 1 minute |
| Operating Temperature | 10 to + 40° C |
Source: Motortronics ME2 Series Micro AC Drive Installation and Start-Up Manual
All Motortronics ME2 Series documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What is the maximum input fuse size for the ME2-1P2 model?
The maximum input fuse size is 8 Amps.
From: Motortronics ME2 Series Micro AC Drive Installation and Start-Up Manual
What wire size is recommended for the control wiring of the ME2-203 model?
The recommended control wire size is 14-12 AWG.
From: Motortronics ME2 Series Micro AC Drive Installation and Start-Up Manual
What safety precautions should be taken during installation?
Disconnect main power and wait until the LED on the main control board goes out before working on the control. Do not service equipment with voltage applied.
From: Motortronics ME2 Series Micro AC Drives Installation & Start-Up Manual
What are the mounting options for the ME2 Series?
The unit can be mounted directly or on a DIN rail (for < 1 HP drives).
From: Motortronics ME2 Series Micro AC Drives Installation & Start-Up Manual
What is the tightening torque for the power terminal block?
The tightening torque for TM1 is 1 lbs-ft or 12 lbs-in.
From: Motortronics ME2 Series Micro AC Drives Installation & Start-Up Manual
Can the keypad be removed from the drive?
No, the keypad operator cannot be removed.
From: Motortronics ME2 Series Micro AC Drives Installation & Start-Up Manual