This manual describes the installation, startup and operation of Motortronics ME2 series variable frequency AC drives.
This manual provides installation and start-up instructions for the Motortronics ME2 Series Micro AC Drives. It covers general information, specifications, and mounting dimensions for the drive unit. The guide details power and control wiring practices, including terminal block locations and wiring diagrams for various models.
| Input Voltage (Single Phase) | 110 ~ 120V or 200 ~ 240V |
|---|---|
| Input Voltage (Three Phase) | 380 ~ 460V |
| Control Method | Sinusoidal wave PWM control |
| Overload Protection | 150% for 1 minute |
| Operating Temperature | 10 to + 40° C |
The tightening torque for TM1 is 1 lbs-ft or 12 lbs-in.
No, the keypad operator cannot be removed.