Mettler Toledo M100 DR Manuals

ManualLib has 2 documents for the Mettler Toledo M100 DR (Analyzer): 1 product leaflet, 1 user manual. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 1User Manual 1

Key facts

Model
M100 DR
Category
Analyzer
Industry
Industrial
Documents
2
Languages
FR · ZH
Last added
2026-11-22

Start here

Mettler-Toledo M100 DR Transmitter Operating Instructions

Mettler-Toledo M100 DR Transmitter Operating Instructions

User Manual 60 pages · 2.6 MB · ZH

The operating instructions describe the Mettler-Toledo M100 DR, a DIN rail transmitter with HART communication for analytical measurement. The document identifies the M100 DR as a single-channel, multi-parameter transmitter for pH/ORP, pH/pNa, dissolved oxygen and conductivity, and notes that it supports ISM sensors.

The manual covers safety notes, function and design, wiring including HART system architecture, operation via a setup tool or HART handheld, sensor calibration, setup, diagnostics and service, technical data, pH buffer tables and warranty information. This manual is written in Chinese.

Read online

Mettler Toledo M100 DR specifications

HART communicationStandard HART communication
Mounting35 mm DIN rail systems
Width22.5 mm
Analog output4 to 20 mA with HART
Supply voltage14 to 30 V DC
Ambient operating temperature-20 to 60 °C
Maximum probe cable length80 m
Enclosure classificationIP 20
Weight0.5 kg
Galvanic isolationUp to 500 V between inputs, outputs and ground

Source: Mettler Toledo M100 DR 2-Wire Analytical Transmitter Product Leaflet

All Mettler Toledo M100 DR documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What does the Mettler Toledo M100 DR measure?

It measures pH/redox, pH/pNa, oxygen and conductivity. It is described as a single-channel, multiparameter transmitter.

From: Mettler Toledo M100 DR 2-Wire Analytical Transmitter Product Leaflet

Does the M100 DR have HART communication?

Yes. HART communication is standard, and configuration can be done through a HART handheld terminal or other HART asset management tools.

From: Mettler Toledo M100 DR 2-Wire Analytical Transmitter Product Leaflet

What measurement parameters does the M100 DR support?

The M100 DR is described as a single-channel, multi-parameter transmitter for pH/ORP, pH/pNa, dissolved oxygen and conductivity.

From: Mettler-Toledo M100 DR Transmitter Operating Instructions

What kind of transmitter is the M100 DR?

It is a single-channel, multi-parameter transmitter used for analytical measurement, and it only supports ISM sensors.

From: Mettler-Toledo M100 DR Transmitter Operating Instructions