Key facts
- Brand
- Kikusui
- Model
- TOS5052
- Category
- Other Electronics
- Documents
- 2
- Languages
- EN
- Last added
- 2023-11-03
Start here

Kikusui TOS5052 Withstanding Voltage Tester Operation Manual
This is the operation manual for the Kikusui TOS5052, a withstanding voltage tester that generates high voltage for dielectric testing. The manual opens with extensive warnings and cautions, noting that incorrect handling of the tester may cause death by electric shock, and instructs that it be used only by qualified personnel with electrical knowledge.
The manual explains how to operate the tester, including the interlock protection that must be released before the tester will start, test leadwire connection, keylock and test settings, remote control and signal I/O connectors, and optional accessories such as the RC01-TOS/RC02-TOS remote control boxes, HP01A-TOS/HP02A-TOS probe-type leads, and the warning light unit. It applies to testers with PROGRAM version number 1.0X.
Kikusui TOS5052 specifications
| Output‑voltage range | 0.05 kV to 5.00 kV |
|---|---|
| Maximum rated load | 500 VA |
| Output‑voltage accuracy | +(1.5 % of setting + 20 V) |
| Current measurement range | 0.00 mA to 110 mA |
| Test‑time setting range | 0.3 s to 999 s |
| Frequency | 50 Hz/60 Hz |
All Kikusui TOS5052 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
Why won't my Kikusui TOS5052 start when I first unpack it?
The tester has an interlock protection that is effective on arrival, so it will not start its operation. You must release the interlock protection before operation, as described in the "Interlock Function" section.
From: Kikusui TOS5052 Withstanding Voltage Tester Operation Manual
Which program version does this TOS5052 manual cover?
This manual is applicable to testers whose PROGRAM version number is 1.0X. The version can be found via Section 3.3 "Checking the Tester Operation."
From: Kikusui TOS5052 Withstanding Voltage Tester Operation Manual
Which safety standards does the TOS9200 series comply with?
It complies with IEC, EN, VDE, BS, UL, CSA, JIS and the Electrical Application and Material Safety Law of Japan.
How many test steps can be stored in the TOS9200 series?
The instrument can store up to 500 steps and 100 programs.