Janitza UMG 96 Manuals

ManualLib has 3 documents for the Janitza UMG 96 (Other Electronics): 2 user manuals, 1 product leaflet. Every file can be read online or downloaded as a PDF for free.

User Manual 2Product Leaflet 1

Key facts

Brand
Janitza
Model
UMG 96
Documents
3
Languages
DE · EN
Last added
2026-10-15

Start here

Janitza UMG 96 RM Power Analyzer User Manual

Janitza UMG 96 RM Power Analyzer User Manual

User Manual 104 pages · 723 KB · EN

This manual covers the safe handling, installation, and operation of the Janitza UMG 96 RM power analyzer. It includes safety warnings, inspection procedures, and detailed instructions for connecting power, voltage, and current measurement circuits.

The document also provides technical data such as installation depth, supply voltage ranges, frequency range, measurement capabilities, and interface options like RS485 and digital outputs. Programming mode functions and calibration guidelines are described for qualified personnel.

Read online

Janitza UMG 96 specifications

Installation depth45 mm
Supply voltage (230 V option)90 V – 277 V (50/60 Hz) or DC 90 V – 250 V
Supply voltage (24 V option)24 V – 90 V AC / 7 V DC; 150 V CAT I
Frequency range45 Hz – 65 Hz
Voltage measurement capability3‑phase up to 300 V
Current measurement capability3‑phase via current transformer (CT)
RS485 interfaceAvailable
Digital outputs2

Source: Janitza UMG 96 RM Power Analyzer User Manual

All Janitza UMG 96 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the UMG 96RM used for?

The device measures and calculates electrical parameters such as voltage, current, power, energy, and harmonics delivered to distribution systems.

From: Janitza UMG 96RM Energy Analyzer Operation Manual

What is the maximum voltage rating for the device's inputs?

The voltage measurement input supports a nominal voltage of up to 300V.

From: Janitza UMG 96RM Energy Analyzer Operation Manual

How do I switch the device to programming mode?

Press buttons 1 and 2 together for about one second to enter programming mode.

From: Janitza UMG 96 RM Power Analyzer User Manual

What is the installation depth of the UMG 96 RM?

The device requires an installation depth of 45 mm.

From: Janitza UMG 96 RM Power Analyzer User Manual

What is the operating temperature range for the UMG 96?

The device operates between -10°C and +55°C.

From: Janitza UMG 96 Energy Meter Technical Data Sheet

Can the UMG 96 measure high voltage ranges?

Yes, it supports measuring ranges up to 87-476 V AC L/L.