FLECK 5810 & 5812 XTR2 Water Softener Control Valve Service Manual
This service manual provides detailed instructions for the FLECK 5810 and 5812 XTR2 water softener or filter control valves. It covers operating parameters, installation procedures, and the features of the XTR2 touchscreen control interface. The document includes guidance on master settings programming, startup flushing, system disinfection, and troubleshooting alarms and errors.
Read onlineFleck 5812 XTR2 specifications
| Minimum Pressure | 20 psi/1.4 bar/138 kPa |
|---|---|
| Maximum Pressure | 125 psi/8.61 bar/861 kPa |
| Minimum Water Temperature | 34°F/1°C |
| Maximum Water Temperature | 110°F/43°C |
| Input Voltage | 100-240 VAC |
| Output Voltage | 12 VDC |
| Output Current | 2.0 amps |
Source: FLECK 5810 & 5812 XTR2 Water Softener Control Valve Service Manual
All Fleck 5812 XTR2 documents by type
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
What is the maximum pressure rating for the FLECK 5810 & 5812?
The maximum pressure rating is 125 psi (8.6 bar).
From: FLECK 5810 & 5812 XTR2 Water Softener Control Valve Service Manual
What is the minimum water temperature required for operation?
The minimum water temperature required is 34°F (1°C).
From: FLECK 5810 & 5812 XTR2 Water Softener Control Valve Service Manual
What is the maximum water temperature for this valve?
The maximum water temperature is 110°F (43°C).
From: FLECK 5810 & 5812 XTR2 Water Softener Control Valve Service Manual
What type of lubricant should be used for the O-ring seals?
Only silicone lubricant should be used for the distributor and tank O-ring seals.
From: FLECK 5810 & 5812 XTR2 Water Softener Control Valve Service Manual
What is the maximum water pressure for the valve?
The maximum pressure is 125 psi (8.61 bar/861 kPa).
From: Fleck 5810 & 5812 XTR2 Water Softener or Filter Control Valve Service Manual
What input voltage does the control use?
The control uses an input voltage of 100-240 VAC.
From: Fleck 5810 & 5812 XTR2 Water Softener or Filter Control Valve Service Manual