Asundar ASD863+651 Manuals

ManualLib has 3 documents for the Asundar ASD863+651 (Analyzer): 3 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 3

Key facts

Brand
Asundar
Model
ASD863+651
Category
Analyzer
Documents
3
Languages
ZH
Last added
2023-11-10

Start here

Asundar ASD863+651 Fast Charger Adapter Tester User Manual

Asundar ASD863+651 Fast Charger Adapter Tester User Manual

User Manual 28 pages · 3.6 MB · ZH

This user manual describes the Asundar ASD863+651 fast charger adapter tester, which consists of a multi-protocol load instrument, an ASD651 PF digital power meter, and an Android operating terminal. It is used for functional testing, parameter testing and performance evaluation of power adapter PCBA boards and finished products.

The manual covers unpacking and installation, quick start with front and rear panel descriptions, technical specifications, equipment connections, and basic operation including R&D mode and automatic test modes (ALONE, 2&2 and 4IN1). The load instrument integrates four independent programmable multi-protocol electronic load modules compatible with QC and PD fast charging protocols, and the power meter integrates four independent AC test modules with an isolation transformer. Test results can be exported to USB storage devices. This manual is written in Chinese.

Read online

Asundar ASD863+651 specifications

Channels4 (CH1–CH4)
Voltage measurement range0~24V
Current measurement range0~10A rated
Power rating100W; 150W in production automatic test
Supported protocolsQC2.0/PD2.0/QC3.0/PD3.0/PPS/AFC/FCP/SCP/SSCP/VOOC/SVOOC
Setting resolutionVoltage 1mV, current 1mA
Readback accuracy (25°C)Voltage ±(0.1%+0.025%FS), current ±(0.1%+0.08%FS)
Ripple testFrequency 50Hz–500kHz, voltage 0–3000mV
Power meter adjustable voltage90V/100V/110V/120V/130V/200V/220V/240V/260V
Mains input100~240Vac, 47~63Hz
ControlAndroid touch screen
Communication interfaceDB9/RS232
Operating temperature0 to 40 °C
DimensionsDevice 480×300×110mm; Android screen 370×260×30mm
Weight16kg + 11.8kg + 1.75kg (power meter + load instrument + Android screen)

Source: Asundar ASD863+651 Multi-Protocol AC/DC Test Equipment User Manual

All Asundar ASD863+651 documents by type

Questions answered in these manuals

What should I check if the indicator does not light after powering on?

Check that the device is powered and the power cord and switch are correctly connected, verify the mains parameters match the requirements, and check whether the fuse is blown; if the fault persists, contact the supplier.

From: Asundar ASD863+651 Multi-Protocol AC/DC Test Equipment User Manual

How do I replace the fuse?

Unplug the power cord, remove the fuse holder with a small screwdriver, replace the fuse with one of the same specification, and reinstall it.

From: Asundar ASD863+651 Multi-Protocol AC/DC Test Equipment User Manual

What should I check if the tester's indicator does not light up after power-on?

Check that the device is powered and the power cord and switch are correctly connected, verify the mains parameters meet requirements, and check whether the fuse is blown. If the fault persists, contact the supplier.

From: Asundar ASD863+651 Fast Charger Adapter Tester User Manual

How do I replace the fuse?

Unplug the power cord, use a small screwdriver to remove the fuse holder, replace the fuse with one of the same specification, and restore it.

From: Asundar ASD863+651 Fast Charger Adapter Tester User Manual

What AC input does the device require?

The AC supply must be 100-240 Vac at 47-63 Hz.

From: Asundar ASD863+651 Multi-Protocol Multi-Channel Programmable AC/DC Testing Device User Manual

How many load channels does the tester have?

It has four load channels: CH1, CH2, CH3, and CH4.