This manual provides operating instructions for the YTC5980 intelligent battery discharge monitor, covering setup, operation, data management, and maintenance.
The YTC5980 Intelligent Battery Discharge Monitor is designed for verification discharge tests, capacity testing, daily maintenance of battery banks, engineering acceptance, and DC power load capability testing. It utilizes wireless communication technology to monitor the discharge process in real-time via PC software, tracking individual cell voltages without complex cabling. This manual is written in Chinese.
| Discharge Current Range (48V) | 0~150A / 0~200A / 0~300A |
|---|---|
| Discharge Current Range (220V) | 0~30A / 0~50A / 0~100A |
| Discharge Current Range (380V) | 0~20A / 0~50A / 0~100A |
| Voltage Measurement Accuracy | 0.5% |
| Current Measurement Accuracy | 1% |
| Sampling Interval | 5s~1min |
| Screen Resolution | 128×64LCD |
The system allows a sampling interval ranging from 5 seconds to 1 minute.
Yes, it can perform a short-term discharge of 10 minutes to estimate the battery bank's capacity.
Data can be saved to a USB drive via the device interface and imported into PC management software for analysis.