This document is the user manual for the Yamatake SVP3000 Alphaplus intelligent valve positioners, specifically models AVP100 and AVP102. It covers essential safety precautions, unpacking, and storage requirements to ensure safe operation and longevity of the device. The manual details the installation process, including assembly of the feedback shaft, mounting steps, pneumatic supply requirements, and electrical wiring principles. This manual is written in Chinese.

What's inside

  • Safety Precautions
  • Installation Steps
  • Pneumatic Supply
  • Initial Adjustment
  • Electrical Wiring
  • Automatic Setting
  • Zero-Range Adjustment
  • HART Communication
  • Maintenance
  • Troubleshooting

Specifications

Input Signal Range4-20mA or HART signal
Output Signal4-20mA
Operating Temperature (Ex ia IIC T4-T6)-20°C to +60°C
Operating Temperature (Ex ia IIC T5)-20°C to +60°C
Operating Temperature (Ex ia IIC T6)-20°C to +40°C
Maximum Cable Capacitance0.06 µF
Maximum Cable Inductance1 mH

Frequently asked questions

What are the safety symbols used in this manual?

The manual uses three types of safety instructions: Warning (potential danger leading to death or serious injury), Caution (potential danger leading to minor injury or equipment damage), and Note (useful information for the user).

What is the recommended pipe diameter for the air supply?

The recommended air supply pipe should have an inner diameter of 6mm, preferably using piping with an outer diameter of 10mm.

Which communication devices can be used with the AVP100/102?

The device supports manual communication, the Yamatake SFC160/260 field intelligent communicator, and the Emerson 275 HART communicator (for AVP102).

What is the minimum dew point required for the air supply?

The air must be dry, with a dew point at least 10°C lower than the SVP's minimum ambient operating temperature.