Vishay Siliconix SiP32419EVB/SiP32429EVB Evaluation Board Manual

Vishay Siliconix evaluation board manual for the SiP32419EVB and SiP32429EVB load switches, covering board connections, protection settings, schematic…


Vishay Siliconix SiP32419EVB/SiP32429EVB Evaluation Board Manual - cover page
Brand
Vishay Siliconix
Category
Power Management
Document type
User Manual
Language
English
Pages
7
File format
PDF
File size
364 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
5DEF576A6EE08546D75A9F872F26E33E

About this manual

This manual describes the Vishay Siliconix SiP32419EVB and SiP32429EVB evaluation board for evaluating the over-current protection and programmable soft-start functions of the load switch. It covers power input and output terminals, test points, input and output capacitors, the enable terminal, fault and power-good flags, current-limit setting, and soft power-up calculations.

The document also includes the evaluation board schematic, PCB layout layers, bill of materials, and lab experiment results for power-up and output-short conditions.

What's inside

  • Evaluation Board Description
  • Power Input and Output Terminals
  • Input and Output Capacitors
  • Enable Terminal
  • Fault Flag and Power Good Flag
  • Over Current Limit Setting
  • Programmable Soft Power Up
  • Evaluation Board Schematic
  • Evaluation Board Layout
  • Bill of Materials and Lab Experiment Results

Specifications

Switch on-resistance56 mΩ
Operating voltage range6 V to 28 V
Evaluation board input voltage range6 V to 24 V
Over-current shutdown timeMore than 7 ms
Over-temperature shutdown thresholdAbout 145 °C junction temperature
Over-temperature hysteresisAbout 20 °C
Enable pin voltage rating6 V
Enable threshold voltage1.5 V
Disable threshold voltage0.4 V or lower
Input and output capacitor capacitance10 μF
Input and output capacitor voltage rating50 V
Soft-start charge current5 μA
PackageDFN10 3 mm x 3 mm
Measured current limit1.365 A
Calculated current limit1.5 A

Frequently asked questions

What is the input voltage range for the SiP32419EVB and SiP32429EVB evaluation board?

The evaluation board input voltage range is from 6 V to 24 V, while the devices themselves can operate normally up to 28 V.

How is the over-current limit set on the evaluation board?

The current limit is set with the RSET resistor, which is R5 on the board, using the current limit formula given in the manual.

What happens when an over-current fault occurs?

If the over-current condition persists for more than 7 ms, the switch shuts off automatically and the FLG pin is pulled low.

How is the soft power-up time controlled?

The soft power-up time is set by the built-in ISS charge current, the CSS capacitor (C9 on the board), the current limit resistor, and the output resistor.

Download PDF (364 KB)

More Vishay Siliconix Manuals


View all Vishay Siliconix manuals →