TRINAMIC USB-2-SD TMCL Firmware Manual

TRINAMIC USB-2-SD TMCL firmware manual (V1.14) covering the one-axis ramp generator module, its setup, TMCL commands, axis and global parameters.


TRINAMIC USB-2-SD TMCL Firmware Manual - cover page
Brand
Trinamic
Category
Other Electronics
Document type
Programming Manual
Language
English
Pages
103
File format
PDF
File size
972 KB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
1D9FE3721F8558828400F68D00943465

About this manual

This is the TMCL firmware manual for the TRINAMIC USB-2-SD, a one-axis ramp generator module with a TTL level step/direction output and an ABN encoder input. The module has a USB interface, is USB powered, and can generate linear ramps, SixPoint ramps and S-shaped ramps. Typical use is table-top testing of motor drivers with step/direction inputs. It is written for firmware version V1.14 (document revision V1.01, 2020-JAN-21).

The manual starts with first steps in TMCL and the TMCL-IDE, then explains the binary command and reply format, gives an overview of TMCL commands by subject and detailed descriptions of each command from ROR and MVP to the calculation, branch and interrupt commands. It also lists axis parameters and the global parameter banks, and closes with hints and tips on encoders, velocity and acceleration calculation, and TMCL programming techniques. Note that the module has no EEPROM, so downloaded TMCL programs reside only in RAM and are lost when the module is unplugged.

What's inside

  • Features
  • First Steps with TMCL
  • TMCL and the TMCL-IDE – An Introduction
  • TMCL Command Overview
  • Detailed TMCL Command Descriptions
  • Axis Parameters
  • Global Parameters
  • Hints and Tips
  • TMCL Programming Techniques and Structure
  • Supplemental Directives

Specifications

AxesOne axis ramp generator
OutputTTL level step/direction output
Encoder inputABN encoder input
USB interfaceUSB full speed (12Mbit/s) device interface
I/O voltage5V
Ramp typesLinear, SixPoint and S-shaped ramps selectable
Program memoryUp to 577 TMCL commands
Firmware versionV1.14
Document revisionV1.01, 2020-JAN-21

Frequently asked questions

What software do I need for the USB-2-SD?

You need a PC with Windows (at least Windows 7) or Linux and the TMCL-IDE 3.x installed; it can be downloaded from the TMCL-IDE product page of Trinamic's website.

Are TMCL programs kept after unplugging the module?

No. The module has no EEPROM, so downloaded TMCL programs reside only in RAM and are gone after unplugging it from the USB interface.

What ramp types can the USB-2-SD generate?

It can generate linear ramps, SixPoint ramps and S-shaped ramps.

How is the module connected and powered?

It is USB powered and can be plugged directly into a USB port of a computer, or connected through a USB extension cable.