TRINAMIC TMCM-343 3-Axis Stepper Controller Hardware Manual

This document provides the hardware manual and functional description of the TMCM-343 3-axis stepper controller/driver module by Trinamic Motion Control GmbH & Co. KG. The module has a nominal supply voltage range of 8V to 34V DC and supports a current range of 300mA to 1.1A RMS. The module supports TMCL™/CANopen firmware and various communication interfaces including CAN 2.0b, RS232, and RS485. Additionally, the module features stallGuard™ sensorless motor stall detection, reference switches, and other input/output functionalities.


TRINAMIC TMCM-343 3-Axis Stepper Controller Hardware Manual - cover page
Brand
Trinamic
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
27
File format
PDF
File size
763 KB
Published
30 December, 2022
Updated
27 September, 2023
MD5 checksum
22B22E8D6ABFAAC547D6F14A7B3AE895

About this manual

The TMCM-343 is a compact and versatile triple axis 2-phase stepper motor controller and driver module designed for embedded applications. It provides a complete motion control solution at a very small size, featuring integrated additional I/Os for complete system control applications. The module supports both stand-alone operation using the TMCL™ language and remote controlled operation via PC.

What's inside

  • Features
  • Order codes
  • Electrical and mechanical interfacing
  • Operational ratings
  • Functional description
  • Putting the TMCM-343 into operation
  • Migrating from the TMCM-303
  • TMCL
  • CANopen

Specifications

Axis count3-axis
Coil current300mA to 1.1A RMS
Supply voltage8V to 34V DC
Peak current1.5A
MicrosteppingUp to 64 times
EEPROM storage16 KByte
Dimensions80 x 50 x 8 mm

Frequently asked questions

What is the nominal supply voltage range?

The nominal supply voltage ranges from 8V to 34V DC.

Does the module support sensorless stall detection?

Yes, it includes the optional stallGuard™ feature for sensorless motor stall detection.

What communication interfaces are supported?

Host communication is possible via the serial UART interface (RS232 or RS485) or via CAN.