Trinamic TMCM-302 Stepper Motor Motion Control Module Documentation

Documentation for the Trinamic TMCM-302 triple-axis stepper motor motion control module, covering features, connections, operation and specifications.


Trinamic TMCM-302 Stepper Motor Motion Control Module Documentation - cover page
Brand
Trinamic
Category
stepping motor
Document type
User Manual
Language
English
Pages
29
File format
PDF
File size
413 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
99485D2A954E3F89E941CDFD87D44E96

About this manual

The Trinamic TMCM-302 is a triple-axis 2-phase stepper motor motion control module based on the TMC428 motion controller. It creates Step and Direction signals for external power driver modules and can also be used with external stepper motor drivers that have an SPI interface.

The module can be remote controlled through CAN, RS-232 or RS-485, and stand-alone operation is possible with TMCL programs stored in the on-board EEPROM. The documentation covers ordering information, main features, operational conditions, ramp profiles, module connections, setup and operational calculations.

What's inside

  • General Description
  • Ordering Information
  • Main Features
  • Operational Conditions
  • Ramp Profiles
  • Getting Started
  • Connecting the Module
  • Putting the TMCM-302 into Operation
  • Operational Description
  • Appendix A: Further Documentation

Specifications

Stepper motors supportedUp to three 2-phase stepper motors
Motion controllerTMC428
Host interfacesCAN 2.0b, RS-232, RS-485
EEPROM16 KByte
Flash memory32 KByte
Full-step frequencyUp to 300 kHz
Module size80 x 50 mm2
Supply voltage4.75 to 5.25 VDC at 5 VDC
Module currentApproximately 300 mA
Input voltage range0 to 5 VDC or TTL level
CAN differential input voltage-8 to +18 VDC
Output current50 mA (microcontroller ports), 35 mA (shift register outputs)
Ambient temperatureUp to 70 C

Frequently asked questions

How many stepper motors can the TMCM-302 control?

It can drive and control up to three 2-phase stepper motors.

Which interfaces can be used to remote-control the TMCM-302?

The module can be remote controlled via CAN, RS-232 or RS-485.

What is the maximum full-step frequency of the TMCM-302?

Full step frequencies are supported up to 300 kHz.

What ambient temperature is the TMCM-302 suitable for?

It is suitable for ambient temperatures up to 70 C.

Download PDF (413 KB)