Tosoh TSKgel NH2-100 DC 3 μm Column Supplementary Manual

Supplement to the Tosoh TSKgel NH2-100 3 μm column instruction manual: installation, flow rate and pressure drop, guard column and quality standards.


Tosoh TSKgel NH2-100 DC 3 μm Column Supplementary Manual - cover page
Brand
TOSOH
Category
Chemical products
Document type
User Manual
Language
Chinese
Pages
5
File format
PDF
File size
367 KB
Published
09 November, 2026
Updated
09 November, 2026
MD5 checksum
16F3D928DBB1F2C590387EE693814FFF

About this manual

This document is a supplementary instruction manual from Tosoh for the TSKgel NH2-100 DC 3 μm normal-phase HPLC column, supplied in a 4.6 mm I.D. × 5 cm L size. It only describes the points that differ from the standard TSKgel NH2-100 3 μm column instruction manual, which should be read first for the safety notes and general handling instructions.

The supplement covers the column's end fitting with an external male connector for direct connection to another HPLC column, the parts of the column, installation and connection cautions, the recommended flow rate and maximum pressure drop, the matching guard column, and the quality standard table with theoretical plate count and asymmetry factor. This manual is written in Chinese.

What's inside

  • 简介 (Introduction)
  • 色谱柱部件 (Column parts)
  • 安装色谱柱 (Installing the column)
  • 流速和压降 (Flow rate and pressure drop)
  • 保护柱的种类和选择 (Guard column types and selection)
  • 质量标准和质量保证 (Quality standards and quality assurance)

Specifications

Part number0021999
Column dimensions4.6 mm I.D. × 5 cm L
Recommended flow rate1.0 mL/min
Maximum pressure drop5 MPa
Theoretical plates6,000 TP/column
Asymmetry factor0.90 to 1.30
Guard columnTSKgel guardgel NH2-100 3 μm, 3.2 mm I.D. × 1.5 cm L (part no. 0021972)
Guard column cartridges per box3
Maximum tightening torque when joining two columns2.0 N·m (about 30°)

Frequently asked questions

What is the recommended flow rate for the TSKgel NH2-100 DC 3 μm column?

The recommended flow rate is 1.0 mL/min, with a maximum pressure drop of 5 MPa.

Which guard column fits this column?

TSKgel guardgel NH2-100 3 μm, 3.2 mm I.D. × 1.5 cm L (part no. 0021972); each box contains three guard column cartridges.

What are the theoretical plate count and asymmetry factor of the column?

The quality standard table gives 6,000 theoretical plates per column and an asymmetry factor of 0.90 to 1.30.

How should the column be connected directly to another HPLC column?

First connect the column outlet and the other column inlet by hand, then tighten with a suitable wrench and check for solvent leaks; torques above 2.0 N·m may permanently damage the column.