TOSOH TSK-GEL Amide-80 Series Packed Column Instruction Manual

The TOSOH TSK-GEL Amide-80 Series instruction manual provides safety guidelines, installation steps, operation tips, maintenance procedures, and…


TOSOH TSK-GEL Amide-80 Series Packed Column Instruction Manual - cover page
Brand
TOSOH
Category
Other
Document type
User Manual
Language
English
Pages
17
File format
PDF
File size
558 KB
Published
30 September, 2026
Updated
30 September, 2026
MD5 checksum
384A78046ABDE2BC8B4C5EE92F272EBD

About this manual

This manual explains the safe handling of TSK‑GEL Amide‑80 packed columns, including fire‑hazard warnings, ventilation requirements, and personal protective equipment. It also details the required documentation that should accompany each column shipment.

The guide covers column installation, recommended flow rates, solvent preparation, temperature limits, routine maintenance, guard‑column replacement, and troubleshooting of common issues such as clogging or loss of resolution. Technical specifications and warranty information are provided in the final sections.

What's inside

  • General Information
  • Unpacking
  • Column Parts
  • Column Installation
  • Column Maintenance
  • Solvent Selection and Preparation
  • Flow Rate
  • Temperature
  • Sample Preparation
  • Troubleshooting

Specifications

pH range2.0‑7.5
Recommended linear velocity6 cm/min (0.05 mL/min for 1.0 mm I.D., 0.20 mL/min for 2.0 mm I.D., 0.43 mL/min for 3.0 mm I.D., 1.00 mL/min for 4.6 mm I.D.)
Column dimension example4.6 mm I.D. × 25 cm (TSK‑gel Amide‑80 5 µm)

Frequently asked questions

What safety precautions are required when using the TSK‑GEL Amide‑80 columns?

Keep the columns away from fire, use them only in well‑ventilated areas, and wear protective eye gear and gloves to avoid skin contact with organic solvents.

How should the column be installed?

Connect the union nut to a 1/16" O.D. capillary tubing, confirm the flow direction on the column label, purge air, and start the solvent at half the intended flow rate.

What flow rate should be used for the first run?

Set a linear velocity of 6 cm/min, which corresponds to 0.05 mL/min for a 1.0 mm I.D. column, 0.20 mL/min for 2.0 mm I.D., 0.43 mL/min for 3.0 mm I.D., and 1.00 mL/min for 4.6 mm I.D.

How should the column be stored when not in use?

Purge the system with the packed solvent, cap both ends of the column, and store it at a relatively constant temperature, avoiding freezing.