TI MSP430 IEC60730 Software Package User's Guide

User guide for the TI MSP430 IEC60730 software package for F5xx, FR57xx, G23xx, G24xx, G25xx, G2x44, and G2x55 devices.


TI MSP430 IEC60730 Software Package User's Guide - cover page
Brand
TI
Category
Other software
Document type
User Manual
Language
English
Pages
64
File format
PDF
File size
2.9 MB
Published
11 November, 2026
Updated
11 November, 2026
MD5 checksum
174DC0FB86078C38B2A4CEE37D7340F1

About this manual

This guide describes the Texas Instruments MSP430 IEC60730 software package, which provides system tests for IEC 60730-1:2010 requirements up to Class B products. It covers example projects, power-on and periodic self-tests, and integration of those tests into an application design.

The document also explains how to generate CRC-CCITT checksums, start new projects in Code Composer Studio or IAR, run ADC, CPU register, clock, memory, GPIO, and program counter tests, and use the configuration tool to generate customized header files.

What's inside

  • Introduction
  • API relation to Table H.1 in IEC60730:2010 standard
  • Running IEC60730 example projects
  • Generating CRC-CCITT Checksums
  • Starting a New IEC60730 project
  • Analog-to-Digital Converter Test
  • CPU Registers Test
  • Clock Fail Test
  • Non Volatile Memory Test
  • General Purpose I/O Test

Specifications

Supported tool chainsTexas Instruments Code Composer Studio v5.3 or later; IAR Embedded Workbench v5.51.3 or later
Default main clock frequency12 MHz
Default percent frequency drift+/-3%
Default RAM testMarch X algorithm in non-destructive mode
Default stack size80 Bytes
Default ADC count drift limits-50 and 50
CRC checksum location for MSP430G2553Information memory (0x1004)
CRC checksum location for MSP430F5529Beginning of Info D section (0x1800)
CRC checksum location for MSP430FR5739Beginning of Info A section (0x1880)

Frequently asked questions

Which IEC 60730 software class does this package support?

The package provides system tests required by IEC 60730-1:2010 for up to Class B products.

How do the example projects report test results?

They toggle the FAILURE pin a number of times to indicate which test failed, and the SUCCESS pin remains set if none of the tests failed.

What is IEC60730_FAIL_SAFE_failSafe?

It is a user-defined function that needs to ensure the application shuts down gracefully.

Which tool chains are supported?

Texas Instruments Code Composer Studio v5.3 or later and IAR Embedded Workbench v5.51.3 or later.