Temposonics R-Series RH PROFIBUS Linear Position Sensor Data Sheet

Data sheet for the Temposonics R-Series RH PROFIBUS magnetostrictive linear position sensor: PROFIBUS-DP output, stroke lengths to 7620 mm, IP67.


Temposonics R-Series RH PROFIBUS Linear Position Sensor Data Sheet - cover page
Brand
Temposonics
Category
sensor
Document type
Datasheet
Language
English
Pages
11
File format
PDF
File size
1.3 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
2F06E4B09EF3E9AC16FD03879A95D7D1

About this manual

This data sheet covers the Temposonics R-Series RH PROFIBUS, a rod-style magnetostrictive linear position sensor designed for installation into a hydraulic cylinder. The document describes the time-of-flight measuring principle, lists technical data such as the PROFIBUS-DP interface with a maximum of 12 Mbit/s, stroke lengths from 25 to 7620 mm, resolution, linearity and repeatability figures, and the operating conditions including temperature, humidity, IP67 ingress protection and pressure ratings. It also gives a typical application example in the steel industry.

The data sheet includes technical drawings for the flange variants RH-M/-S/-H/-V, RH-D, RH-T/-U, RH-R and RH-J, connector wiring for the D63, D53 and AXX connection types with M16, M12 and M8 connectors or cable outlets, and a list of frequently ordered accessories such as position magnets, magnet spacers, O-rings and mounting parts with their part numbers.

What's inside

  • Measuring technology
  • Time-of-flight based magnetostrictive position sensing principle
  • Typical application: Steel industry
  • Technical data
  • Technical drawings
  • Connector wiring
  • Frequently ordered accessories

Specifications

Output interfaceIEC 61158 CPF3 PROFIBUS
Data format / transmission ratePROFIBUS-DP slave / maximum 12 Mbit/s
Stroke length25…7620 mm (1…300 in.); RH5-J: 25…5900 mm (1…232 in.)
ResolutionPosition 1…1000 µm (selectable)
Repeatability< ±0.001 % F.S. (minimum ±2.5 μm) typical
Operating temperature−40…+75 °C (−40…+167 °F)
Ingress protectionIP67 with mating connectors correctly fitted
Operating pressure350 bar (5076 psi) / 700 bar (10,153 psi) peak; RH5-J: 800 bar (11,603 psi)
Operating voltage24 VDC (−15/+20 %)
Current consumption110 mA typical
Sensor rod materialStainless steel 1.4306 (AISI 304L); RH-J: 1.4301 (AISI 304)

Frequently asked questions

What is the maximum PROFIBUS data rate of the RH sensor?

The sensor works as a PROFIBUS-DP slave with a maximum transmission rate of 12 Mbit/s.

What is the operating temperature range of the RH PROFIBUS sensor?

The operating temperature range is −40 to +75 °C (−40 to +167 °F).

How does the sensor measure position?

The interaction of the magnetic fields releases a torsional strain pulse that propagates the length of the waveguide; its time of flight is converted into position.

Which stroke lengths are available?

Stroke lengths from 25 to 7620 mm (1 to 300 in.) are available, and 25 to 5900 mm (1 to 232 in.) for the RH5-J version.

Download PDF (1.3 MB)