Data sheet for the Temposonics R-Series RH PROFIBUS magnetostrictive linear position sensor: PROFIBUS-DP output, stroke lengths to 7620 mm, IP67.
This data sheet covers the Temposonics R-Series RH PROFIBUS, a rod-style magnetostrictive linear position sensor designed for installation into a hydraulic cylinder. The document describes the time-of-flight measuring principle, lists technical data such as the PROFIBUS-DP interface with a maximum of 12 Mbit/s, stroke lengths from 25 to 7620 mm, resolution, linearity and repeatability figures, and the operating conditions including temperature, humidity, IP67 ingress protection and pressure ratings. It also gives a typical application example in the steel industry.
The data sheet includes technical drawings for the flange variants RH-M/-S/-H/-V, RH-D, RH-T/-U, RH-R and RH-J, connector wiring for the D63, D53 and AXX connection types with M16, M12 and M8 connectors or cable outlets, and a list of frequently ordered accessories such as position magnets, magnet spacers, O-rings and mounting parts with their part numbers.
| Output interface | IEC 61158 CPF3 PROFIBUS |
|---|---|
| Data format / transmission rate | PROFIBUS-DP slave / maximum 12 Mbit/s |
| Stroke length | 25…7620 mm (1…300 in.); RH5-J: 25…5900 mm (1…232 in.) |
| Resolution | Position 1…1000 µm (selectable) |
| Repeatability | < ±0.001 % F.S. (minimum ±2.5 μm) typical |
| Operating temperature | −40…+75 °C (−40…+167 °F) |
| Ingress protection | IP67 with mating connectors correctly fitted |
| Operating pressure | 350 bar (5076 psi) / 700 bar (10,153 psi) peak; RH5-J: 800 bar (11,603 psi) |
| Operating voltage | 24 VDC (−15/+20 %) |
| Current consumption | 110 mA typical |
| Sensor rod material | Stainless steel 1.4306 (AISI 304L); RH-J: 1.4301 (AISI 304) |
The sensor works as a PROFIBUS-DP slave with a maximum transmission rate of 12 Mbit/s.
The operating temperature range is −40 to +75 °C (−40 to +167 °F).
The interaction of the magnetic fields releases a torsional strain pulse that propagates the length of the waveguide; its time of flight is converted into position.
Stroke lengths from 25 to 7620 mm (1 to 300 in.) are available, and 25 to 5900 mm (1 to 232 in.) for the RH5-J version.