Temposonics MH-Series MH CANbus Magnetostrictive Linear Position Sensor Data Sheet

Temposonics MH-Series MH CANbus magnetostrictive linear position sensor data sheet with specs, wiring, installation and pressure ratings.


Temposonics MH-Series MH CANbus Magnetostrictive Linear Position Sensor Data Sheet - cover page
Brand
Temposonics
Category
sensor
Document type
Datasheet
Language
English
Pages
12
File format
PDF
File size
4.8 MB
Published
12 November, 2026
Updated
12 November, 2026
MD5 checksum
1ED05B2850CB0DD49C2DBA7729DA8930

About this manual

This data sheet covers the Temposonics MH-Series MH CANbus magnetostrictive linear position sensor for mobile machines and in-cylinder hydraulic applications. It describes the time-of-flight sensing principle, measured position and velocity values, stroke lengths up to 2500 mm, and environmental and pressure ratings.

The document also provides technical data, connector wiring, connection schematics, mechanical installation requirements, and position magnet mounting dimensions for the sensor.

What's inside

  • MEASURING TECHNOLOGY
  • TECHNICAL DATA
  • TECHNICAL DRAWING
  • CONNECTOR WIRING
  • CONNECTION SCHEMATIC
  • MECHANICAL INSTALLATION
  • MECHANICAL INSTALLATION – POSITION MAGNET

Specifications

Stroke length50…2500 mm
Resolution (position)0.1 mm
Resolution (velocity)1 mm/s
Linearity≤ ±0.1 mm (50–250 mm); ±0.04 % F.S. (255–2000 mm); ≤ ±0.8 mm (2005–2500 mm)
Boot up time400 ms (typical)
Cycle timeCANopen: 1 ms (default); SAE J1939: 20 ms (default)
Setpoint tolerance±0.2 mm
Internal sample rate1 ms
Operating temperature (electronics)−40…+105 °C (option −40…+85 °C)
Humidity90 % relative humidity, no condensation
Ingress protection (connector)IP67/IP69K with correctly fitted connectors
Ingress protection (sensor housing)IP67
Operating voltage12/24 VDC nominal (8…32 VDC)
Power drain< 1.5 W
Max inrush current1.5 A/2 ms (1.0 A/2 ms if supply < 13 V)
Supply voltage ripple< 1 % PP
Bus termination120 Ω (HI-LO)
Over voltage protectionUp to +36 VDC
Polarity protectionUp to −36 VDC
Insulation resistanceR ≥ 10 MΩ @ 60 sec
Electric strength500 VDC (DC GND to chassis GND)
Shock100 g (11 ms) single shock per axis; 50 g (11 ms) at 1000 shocks per axis
Pressure ratingsPN 300 bar (Ø7 mm) / 350 bar (Ø10 mm); Pmax 400/450 bar; Pstatic 525/625 bar
Sensor rod diameter7 mm or 10 mm
Bus protocolSAE J1939, CANopen
Measured valuePosition and velocity
Sensor electronics housingStainless steel 1.4305 (AISI 303)
SealingO-ring: HNBR 70
Sensor rod materialStainless steel 1.4301 (AISI 304) for Ø7 mm; 1.4306 (AISI 304L) for Ø10 mm
Null zone30 mm (1.18 in.)
Dead zone63.5 mm (2.49 in.) or 36.5 mm (1.44 in.)

Frequently asked questions

What stroke length range is specified for the MH CANbus sensor?

The specified stroke length range is 50 to 2500 mm.

What position resolution does the sensor provide?

The position resolution is 0.1 mm.

Which bus protocols are supported?

The supported bus protocols are SAE J1939 and CANopen.

What ingress protection rating applies to the sensor housing?

The sensor housing has an ingress protection rating of IP67.

Download PDF (4.8 MB)