Temposonics MH-Series MH CANbus magnetostrictive linear position sensor data sheet with specs, wiring, installation and pressure ratings.
This data sheet covers the Temposonics MH-Series MH CANbus magnetostrictive linear position sensor for mobile machines and in-cylinder hydraulic applications. It describes the time-of-flight sensing principle, measured position and velocity values, stroke lengths up to 2500 mm, and environmental and pressure ratings.
The document also provides technical data, connector wiring, connection schematics, mechanical installation requirements, and position magnet mounting dimensions for the sensor.
| Stroke length | 50…2500 mm |
|---|---|
| Resolution (position) | 0.1 mm |
| Resolution (velocity) | 1 mm/s |
| Linearity | ≤ ±0.1 mm (50–250 mm); ±0.04 % F.S. (255–2000 mm); ≤ ±0.8 mm (2005–2500 mm) |
| Boot up time | 400 ms (typical) |
| Cycle time | CANopen: 1 ms (default); SAE J1939: 20 ms (default) |
| Setpoint tolerance | ±0.2 mm |
| Internal sample rate | 1 ms |
| Operating temperature (electronics) | −40…+105 °C (option −40…+85 °C) |
| Humidity | 90 % relative humidity, no condensation |
| Ingress protection (connector) | IP67/IP69K with correctly fitted connectors |
| Ingress protection (sensor housing) | IP67 |
| Operating voltage | 12/24 VDC nominal (8…32 VDC) |
| Power drain | < 1.5 W |
| Max inrush current | 1.5 A/2 ms (1.0 A/2 ms if supply < 13 V) |
| Supply voltage ripple | < 1 % PP |
| Bus termination | 120 Ω (HI-LO) |
| Over voltage protection | Up to +36 VDC |
| Polarity protection | Up to −36 VDC |
| Insulation resistance | R ≥ 10 MΩ @ 60 sec |
| Electric strength | 500 VDC (DC GND to chassis GND) |
| Shock | 100 g (11 ms) single shock per axis; 50 g (11 ms) at 1000 shocks per axis |
| Pressure ratings | PN 300 bar (Ø7 mm) / 350 bar (Ø10 mm); Pmax 400/450 bar; Pstatic 525/625 bar |
| Sensor rod diameter | 7 mm or 10 mm |
| Bus protocol | SAE J1939, CANopen |
| Measured value | Position and velocity |
| Sensor electronics housing | Stainless steel 1.4305 (AISI 303) |
| Sealing | O-ring: HNBR 70 |
| Sensor rod material | Stainless steel 1.4301 (AISI 304) for Ø7 mm; 1.4306 (AISI 304L) for Ø10 mm |
| Null zone | 30 mm (1.18 in.) |
| Dead zone | 63.5 mm (2.49 in.) or 36.5 mm (1.44 in.) |
The specified stroke length range is 50 to 2500 mm.
The position resolution is 0.1 mm.
The supported bus protocols are SAE J1939 and CANopen.
The sensor housing has an ingress protection rating of IP67.