Temposonics R-Series V RH5 SSI Magnetostrictive Linear Position Sensor Data Sheet

Technical data sheet for Temposonics R-Series V RH5 SSI magnetostrictive linear position sensor with SSI output, resolution up to 0.1 µm, and 10 kHz update…


Temposonics R-Series V RH5 SSI Magnetostrictive Linear Position Sensor Data Sheet - cover page
Brand
Temposonics
Category
Industrial Robot
Document type
Datasheet
Language
English
Pages
13
File format
PDF
File size
1005 KB
Published
06 November, 2026
Updated
06 November, 2026
MD5 checksum
1CC3DD18C7A7FA3137FE88EF82E2AE8C

About this manual

This datasheet details the technical specifications of the Temposonics R-Series V RH5 SSI magnetostrictive linear position sensor. It features high shock and vibration resistance, a minimum resolution of 0.1 µm, and supports synchronous measurement with up to 10 kHz update rate. The sensor uses magnetostrictive technology to measure position via torsional strain pulses. It is available with internal linearization and supports differential measurement between two position magnets. The sensor operates in harsh environments with IP67/68 ingress protection and a wide temperature range of -40°C to +85°C.

What's inside

  • Measuring Technology
  • Technical Data
  • Output Interface
  • Resolution and Update Rate
  • Stroke Length
  • Linearity Deviation
  • Repeatability and Hysteresis
  • Operating Conditions
  • Mechanical Mounting
  • Electrical Connection

Specifications

Output InterfaceSSI (Synchronous Serial Interface) – differential signal in SSI standard (RS-485/RS-422)
Resolution0.1…100 µm (0.0001…0.1 mm)
Update Rate10 kHz
Stroke Length25…7620 mm (1…300 in.)
Operating Temperature-40…+85 °C (−40…+185 °F)
Ingress ProtectionIP67 (connectors correctly fitted)/IP68 (3 m/3 d) for cable outlet/IP68 (3 m/3 d) & IP69 for angled cable outlet
Operating Voltage+12…30 VDC ±20 % (9.6…36 VDC)
Power Consumption1.2 W typical
Linearity Deviation≤ ±40 μm for stroke length ≤ 400 mm
Repeatability< ±0.001 % F.S. (minimum ±2.5 μm)

Frequently asked questions

What is the minimum resolution of the sensor?

The sensor has a minimum resolution of 0.1 µm.

What is the maximum update rate of the sensor?

The sensor supports an update rate up to 10 kHz.

What is the operating temperature range?

The sensor operates from -40°C to +85°C.

What is the ingress protection rating?

The sensor has IP67/68 ingress protection depending on the cable outlet type.

Download PDF (1005 KB)

More Temposonics Manuals