Swagelok R Series proportional relief valves for liquid or gas service, set pressures 10 to 6000 psig, in R3A, R4, RL3 and RL4 versions.
Swagelok R Series proportional relief valves are for liquid or gas service and open gradually as system pressure increases. Set pressures range from 10 to 6000 psig (0.68 to 413 bar), with 1/4 and 1/2 in. and 6 to 12 mm end connections. The series covers high-pressure R3A and R4 valves and low-pressure RL3 and RL4 valves.
The leaflet describes features, operation, back-pressure compensation, pressure-temperature ratings, materials of construction, flow data, dimensions and ordering numbers. It states that the valves do not have a capacity rating at a given pressure rise and are not certified to ASME or any other codes, so the system designer and user must determine when specific safety codes apply and whether these valves conform to them.
| Set pressure range | 10 to 6000 psig (0.68 to 413 bar) |
|---|---|
| High-pressure series working pressure at 70 °F (20 °C) | 6000 psig (413 bar); up to 8000 psig (551 bar) during relief |
| Low-pressure series working pressure | 300 psig (20.6 bar) |
| Set pressure, R3A series | 50 to 6000 psig (3.4 to 413 bar) |
| Set pressure, R4 series | 50 to 1500 psig (3.4 to 103 bar) |
| Set pressure, RL3 and RL4 series | 10 to 225 psig (0.68 to 15.5 bar) |
| Set pressure repeatability | Within ± 5 % at room temperature |
| Body material | 316 SS/A182 |
| Spring material | S17700 SS/AMS 5678 |
| RL3 series orifice | 0.19 in. (4.8 mm) fully open orifice |
| Cleaning and packaging | Swagelok Standard Cleaning and Packaging (SC-10), MS-06-62 |
They open when system pressure reaches the set pressure and close when system pressure falls below the set pressure.
No. The leaflet states that they are not certified to ASME or any other codes, and the system designer and user must determine whether such codes apply.
Multiply the back pressure by 0.8 and subtract the result from the desired set pressure, then pre-set the valve to that value while back pressure is at atmospheric pressure.
Set pressure is the upstream pressure at which the first indication of flow occurs; resealing pressure is the upstream pressure at which there is no indication of flow and is always lower.