Sloan Royal Series Flushometer installation instructions for models 110/111 through 186, including water pressure, warranty, and setup steps.
This document provides installation instructions for Sloan Valve Company’s exposed Royal® flushometers, including closet, urinal, and service sink models for commercial or industrial use. It covers pre-installation checks, rough-in dimensions, and the three-year limited warranty.
The manual lists required tools, water supply pipe preparation, control stop adjustment, and steps to install the flushometer, tailpiece, vacuum breaker, and handle assembly. It also includes care and cleaning guidance and Sloan Technical Support contact information.
| Operating water pressure | 15 to 80 psi (103 to 552 kPa) |
|---|---|
| Maximum static water pressure | 80 PSI (552 kPa) |
| Minimum flowing pressure (high efficiency closets) | 25 psi (172 kPa) |
| Tailpiece adjustment range | 1/2” (13 mm) IN or OUT |
They are designed to operate with 15 to 80 psi (103 to 552 kPa) of water pressure.
Sloan Valve Company warrants the product for three (3) years from date of first purchase.
A straight blade screwdriver and a Sloan A-50 Super-Wrench, Sloan A-109 Plier Wrench or smooth jawed spud wrench are required.
The instructions cover exposed Royal flushometers including Models 110/111, 113, 115, 116, 117, 120, 121, 122, 180, and 186.