Operating instructions for the Siemens SITRANS F C MASS 2100 Di 3-40 Coriolis flow sensor, covering installation, wiring, commissioning, maintenance and…
These operating instructions cover the Siemens SITRANS F C MASS 2100 Di 3-40 Coriolis flow sensor in sizes Di 3, 6, 15, 25 and 40. The sensor is designed for use with SITRANS F C MASS 6000 or SIFLOW FC070 transmitters. The manual describes installation, mounting, wiring, commissioning, service and maintenance, and technical data.
The document includes safety notes, installation precautions, connection schematics, zero point adjustment, recalibration and return procedures, and an appendix with ordering information.
| Mass flow measuring range (Di 3) | 0 ... 250 kg/h |
|---|---|
| Mass flow measuring range (Di 6) | 0 ... 1000 kg/h |
| Mass flow measuring range (Di 15) | 0 ... 5600 kg/h |
| Mass flow measuring range (Di 25) | 0 ... 25000 kg/h |
| Mass flow measuring range (Di 40) | 0 ... 52000 kg/h |
| Temperature range | -50 ... +180 °C |
| Density range | 0 ... 2.9 g/cm3 |
| Enclosure rating | IP 65 (NEMA 4) |
| Measuring pipe material | Stainless steel 1.4435/1.4404 (AISI 316L) or Hastelloy C-22 2.4602 |
| Weight, approx. (sensor only) | 4 to 70 kg depending on size |
The delivery includes the MASS 2100 sensor, Sensorprom, calibration report, Quick Start, and the SITRANS F technical literature CD-ROM.
The sensor is designed for use with SITRANS F C MASS 6000 or SIFLOW FC070 transmitters.
The enclosure is rated IP 65 (NEMA 4).
The temperature range is -50 to +180 °C (-58 to +356 °F).