Siemens SIMODRIVE 611 Digital Drive Converters Configuration Manual

Siemens SIMODRIVE 611 digital drive converter configuration manual covering system setup, motor selection, control units, power modules and cabinet design.


Siemens SIMODRIVE 611 Digital Drive Converters Configuration Manual - cover page
Brand
Siemens
Category
Converter
Document type
Other
Language
English
Pages
490
File format
PDF
File size
7.5 MB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
1AA66F34D821DAB2C080B6CB7DFE63EC

About this manual

The SIMODRIVE 611 Configuration Manual, edition 06/2013, describes a modular drive system based on SIMODRIVE components. Its contents run from the drive system overview and system configuration through motor selection and position/speed sensing, control units, power modules, infeed modules and line supply connection.

The manual also covers important circuit information, cabinet design and EMC, connection diagrams, service and spare parts, and dimension drawings. It addresses machine manufacturing companies (OEMs) that configure, construct and commission a drive line-up based on SIMODRIVE components, and notes that the documentation must be completely read and understood before commissioning.

What's inside

  • Overview of the Drive System
  • System Configuration
  • Motor Selection and Position/Speed Sensing
  • Control Units
  • Power Modules
  • Infeed Modules
  • Line Supply Connection
  • Cabinet Design and EMC
  • Connection Diagrams
  • Service and Spare Parts

Specifications

Equipment series6SN11
Protective conductor minimum cross-section10 mm²

Frequently asked questions

Who is the SIMODRIVE 611 Configuration Manual intended for?

It addresses machine manufacturing companies (OEMs) that wish to configure, construct and commission a drive line-up based on SIMODRIVE components.

What must be done before commissioning the devices?

The documentation must be completely read, understood and taken into account before the devices are commissioned.

Who may perform repairs on SIMODRIVE converters?

Repairs may be performed only by workshops authorized by Siemens, and genuine spare parts must be used.

What protective conductor measure is described for high leakage current?

A permanent PE connection is required at the control cabinet and at the line filter. A copper protective conductor with a minimum cross-section of 10 mm² should be connected, or a second conductor should be connected in parallel.

Download PDF (7.5 MB)