Digital programmable temperature transmitter with two input channels, HART® communication, and redundancy for process industry applications.
This manual describes the Siemens Sitrans TH420 PA2420, a digital, programmable temperature transmitter with two input channels for redundant operation and drift detection. It supports HART® communication and is designed for installation in DIN-compliant connecting heads. The device features galvanic isolation, configurable alarm currents, and supports Pt100 sensors from LABOM. It is suitable for process industry applications and includes SIL2/SIL3 certification for safety-critical environments.
Technical specifications include 4–20 mA output, 24-bit resolution, 100 Hz measuring rate, and temperature ranges from -50°C to 85°C. The transmitter can be configured via HART® and supports various sensor types from LABOM’s GA2200, GA25xx, GA2610, GA27xx, and GA3100 series.
| Output Signal | 4…20 mA, 2-wire technology, HART® |
|---|---|
| Input Type | Pt100 per EN 60751 |
| Measuring Rate | 100 Hz |
| Resolution | 24 Bit |
| Accuracy | ≤ 0.04 °C (when using Pt100, class A) |
| Supply Voltage | 7.5…48 V DC |
| Temperature Range | -50...85 °C |
| Degree of Protection | IP 68 |
| SIL Classification | SIL2, SIL3 with redundant use of two PA2420 |
The output signal is 4…20 mA, 2-wire technology, HART®.
The basic accuracy is ≤ 0.04 °C when using Pt100, class A.
It has SIL2 classification and SIL3 with redundant use of two PA2420.