Schmersal AZM 161ST-12/11RKN-024 solenoid interlock operating and installation instructions covering mounting, electrical connection and maintenance.
The Schmersal AZM 161ST-12/11RKN-024 is a solenoid interlock designed to prevent movable safety guards from being opened before hazardous conditions have been eliminated when used with the control part of a machine. The instructions are addressed to authorised qualified personnel and cover mounting, set-up, commissioning and disassembly.
Content includes the ordering code, technical data, mounting dimensions, manual and emergency release options, contact options, electrical connection, set-up and maintenance, and disassembly and disposal. Listed technical data include a 24 VAC/DC rated control voltage, IP67 protection and a mechanical life of at least 1,000,000 operations.
| Standards | EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1 |
|---|---|
| Housing material | Plastic, glass-fiber reinforced thermoplastic, self-extinguishing |
| Gross weight | 434 g |
| Auxiliary contacts | 2 |
| Safety contacts | 3 |
| B10D, NC contacts | 2,000,000 operations |
| Mechanical life, minimum | 1,000,000 operations |
| Holding force FZh | 2,000 N |
| Locking force Fmax, maximum | 2,600 N |
| Actuator travel | 5.5 mm |
| Positive opening travel | 10 mm |
| Sensor dimensions (L x W x H) | 30 x 130 x 90 mm |
| Protection class | IP67 |
| Operating ambient temperature | -25 to +60 °C |
| Storage and transport temperature | -25 to +85 °C |
| Rated control voltage | 24 VAC/DC |
| Thermal test current | 2 A |
| Power consumption, maximum | 10 W |
| Switching frequency | 1,000/h |
| Contact material, electrical | Silver |
| Safety contact rating, AC-15 | 230 VAC, 4 A |
| Safety contact rating, DC-13 | 60 VDC, 2 A |
It is designed to prevent movable safety guards from being opened before hazardous conditions have been eliminated when used with the control part of a machine.
The rated control voltage is 24 VAC/DC.
No. The solenoid interlock is double insulated and the use of an earth wire is not authorised.
The actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures.