Installation instructions for Rexnord Viva elastomer couplings, types V, VS, and VSX, sizes 110-460, covering safety, hub mounting, element mounting, torque…
This guide provides step-by-step instructions for installing Rexnord Viva elastomer couplings, including safety precautions, hub mounting methods, element mounting options, and torque specifications. It covers types V, VS, and VSX with sizes ranging from 110 to 460. Safety is emphasized throughout, with warnings about lockout-tag out procedures, guarding, and proper handling of rotating components. The document also includes tables for part numbers, set screw torque, and mounting configurations for different coupling sizes and shaft gaps.
| Coupling Types | V, VS, VSX |
|---|---|
| Sizes | 110-460 |
They provide a mechanical connection between rotating shafts to transmit power and torque while accommodating misalignment.
The hub should be heated to 350°F (177°C), and the temperature must not exceed 500°F (260°C).
The guard must have a minimum of 12.7 mm (1/2 inch) radial clearance to the coupling outside diameter.