Rexnord Viva Elastomer Couplings Installation Guide

Installation instructions for Rexnord Viva elastomer couplings, types V, VS, and VSX, sizes 110-460, covering safety, hub mounting, element mounting, torque…


Rexnord Viva Elastomer Couplings Installation Guide - cover page
Brand
Rexnord
Category
Industrial Robot
Document type
Installation Guide
Language
English
Pages
6
File format
PDF
File size
1.1 MB
Published
04 November, 2026
Updated
04 November, 2026
MD5 checksum
15006B92044DC64D2E83B9F49ADDE304

About this manual

This guide provides step-by-step instructions for installing Rexnord Viva elastomer couplings, including safety precautions, hub mounting methods, element mounting options, and torque specifications. It covers types V, VS, and VSX with sizes ranging from 110 to 460. Safety is emphasized throughout, with warnings about lockout-tag out procedures, guarding, and proper handling of rotating components. The document also includes tables for part numbers, set screw torque, and mounting configurations for different coupling sizes and shaft gaps.

What's inside

  • Safety and Advice Hints
  • Hub Mounting
  • Element Mounting
  • Set Screw Torque Specifications
  • Mounting Options for Type V, VS, and VSX

Specifications

Coupling TypesV, VS, VSX
Sizes110-460

Frequently asked questions

What is the purpose of the Rexnord Viva Elastomer Couplings?

They provide a mechanical connection between rotating shafts to transmit power and torque while accommodating misalignment.

What is the maximum temperature for heating carbon steel hubs?

The hub should be heated to 350°F (177°C), and the temperature must not exceed 500°F (260°C).

What is the minimum radial clearance required for the guard to meet ATEX requirements?

The guard must have a minimum of 12.7 mm (1/2 inch) radial clearance to the coupling outside diameter.