Ranger AN2000 AN3000 AN4800 Electric Fencer Operating Manual

Ranger AN2000, AN3000 and AN4800 electric fencer operating manual with safety, installation and solar operation instructions.


Ranger AN2000 AN3000 AN4800 Electric Fencer Operating Manual - cover page
Brand
Ranger
Category
Other Electronics
Document type
User Manual
Language
English
Pages
37
File format
PDF
File size
6.7 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
2E0A012E17273529784AACCF9AFAB782

About this manual

This operating manual covers the Ranger AN2000, AN3000 and AN4800 electric fencers, also called pasture fencers or energizers. It contains general safety instructions and information for installing and operating the devices.

Topics include commissioning with the push button, LED status indications, earthing, connection to a 12 V rechargeable battery or mains adapter, and solar panel alignment, setting and maintenance.

What's inside

  • General Safety Instructions
  • Description and Construction of the Product
  • Installation
  • Commissioning
  • Optimal Solar Alignment and Setting
  • Energizer Operating Description
  • Rechargeable battery indicator

Specifications

Solar panel power<=20W
Mains adapter model47PSU0010EU /UK /US
Recommended solar panel angle50 degrees
Intermediate earth intervalevery 50 m
Mains voltage230V/110V

Frequently asked questions

How do you switch the energizer on or off?

Keep the push button pressed for longer than 2 seconds.

Which mains adapter is used for 230V power supply?

Use the mains adapter 47PSU0010EU /UK /US as specified on the intermediate plate.

What is the recommended solar panel angle for most parts of Europe?

An angle of 50 degrees is optimal for long-term use in most parts of Europe.

How often should the rechargeable battery be recharged during storage?

Recharge the battery every 2 months during longer periods of storage and disconnect it from the energizer.