OPTEX FlipX Series Standard Models Indoor Detector Installation Instructions

OPTEX FlipX series standard indoor detector installation instructions: mounting, wiring, jumper settings, wide/narrow lens setup and walk test.


OPTEX FlipX Series Standard Models Indoor Detector Installation Instructions - cover page
Brand
Optex
Category
sensor
Document type
Installation Guide
Language
English
Pages
13
File format
PDF
File size
3.5 MB
Published
09 November, 2026
Updated
09 November, 2026
MD5 checksum
1AF9751D49797BC28BBBB6A9BFD5CFF6

About this manual

This document is the installation instruction sheet for the OPTEX FlipX series indoor detector, standard models FLX-S-ST, FLX-S-ST-BKT, FLX-S-DT-X5, FLX-S-DT-X5-BKT, FLX-S-DT-X8 and FLX-S-DT-X9. It identifies the parts (cover, main unit, base, lens, sponge, and the CW-G2 mounting bracket supplied with "-BKT" models) and describes wall mount without bracket, wall mount with bracket and ceiling mount with bracket, including how to break the wiring knockouts.

The second half covers wiring to the terminal and power cable length limits, jumper pin settings for LED, Wide/Narrow lens, PIR sensitivity and MW sensitivity, the Wide/Narrow lens setting procedure, the walk test, and the technical specifications and dimensions of the unit. It also lists compliance statements and the microwave emission frequency and power for the DT models.

What's inside

  • Parts identification
  • Wall mount without bracket
  • Wall mount with bracket
  • Ceiling mount with bracket
  • Assemble and connect
  • Jumper pin settings
  • Wide/Narrow setting
  • Walk test
  • Specifications
  • Compliance

Specifications

Detection methodPassive infrared and Microwave
CoverageWide: 12 m (40 ft.) 85° / Narrow: 18 m (60 ft.) 5° (no MW detection at Narrow)
Detection zonesWide: 76 zones / Narrow: 12 zones
Mounting height2.0 to 3.0 m (6'7" to 9'8"); 2.4 m (8') recommended
Power input9.5 to 16 V DC
Current draw8 mA (normal) / 11 mA (normal), 11 mA (max.) at 12 V DC / 14 mA (max.) at 12 V DC
Warm-up periodApprox. 60 s (LED blinks)
Alarm/tamper relay outputN.C. 24 V DC 0.1 A max. (resistive load); tamper opens when the cover is removed
DimensionsH: 129.2 x W: 61.5 x D: 50.9 mm
WeightApprox. 90 g (3.17 oz); approx. 105 g (3.7 oz) with bracket approx. 120 g / 135 g
Microwave emission (DT models)10.525 GHz 15.78 mW e.i.r.p / 10.587 GHz 8.93 mW e.i.r.p / 9.425 GHz 14.50 mW e.i.r.p

Frequently asked questions

What mounting height is recommended for the detector?

The mounting height range is 2.0 to 3.0 m (6'7" to 9'8"), with 2.4 m (8') recommended.

How is the walk test carried out?

Set the LED pin to ON, close the cover and walk in the detection area to check the detecting performance via the LED indication; a walk test should be conducted at least once a year.

What happens when the lens is set to Narrow?

When Narrow is selected, microwave detection is disabled, and the jumper pin must also be set to Narrow.

How long is the warm-up period?

The warm-up period is approximately 60 seconds, during which the LED blinks.