This user manual covers the installation, adjustment, and operation of the Optex OA-72V ceiling-mounted safety system for automatic doors.
The Optex OA-72V is a ceiling-mounted automatic door safety system designed to prevent injury by detecting objects in its sensing area. It utilizes near-infrared reflection technology with an adjustable sensing range and supports various installation heights between 2.0m and 4.0m.
Installation involves cutting a hole for the mounting bracket, connecting power and signal wires (grey for power, yellow for signal), and securing the unit to the ceiling. Users can adjust the depth and left/right angles of the sensing area using specific screws on the device body. This manual is written in Chinese.
| Power Supply | AC/DC 12~110V (50/60HZ) |
|---|---|
| Consumption | 1.5W/5VA or less |
| Output | Relay contact 1a (no voltage) 50V 0.1A max |
| Operating Temperature | -20~+55C (no condensation) |
| Weight | 330g per unit body |
| Installation Height | 2.0~4.0m |
The sensor emits near-infrared light, and detects objects when changes in reflected light are received.
Connect the grey wire to the power supply and the yellow wire to the signal line.
The recommended installation height range is within 2.0m to 4.0m.
Use a screwdriver to adjust the depth adjustment screw located on the device body.