User's guide for the Nordson EFD Performus I industrial fluid dispensing system, covering setup, operation, testing, specifications, parts and troubleshooting.
This User's Guide covers the Performus I dispensing system from EFD, a dispensing system designed specifically for industrial dispensing. It explains the controls and features, recommended testing procedures, system setup, filling the syringe barrel, and includes a troubleshooting guide and settings suggestions based on EFD's industrial dispensing experience.
The guide also contains EFD product safety information, including maximum air pressure limits, warnings on high pressure fluids and halogenated hydrocarbon solvents, intended use restrictions, cleaning and maintenance instructions, disposal guidance, and a China RoHS hazardous material declaration. Contact information for EFD support in the USA, Europe, India and Asia is provided, along with warranty details.
| Cabinet dimensions | 183 mm x 86 mm x 51 mm (7.22" W x 3.38" D x 2" H) |
|---|---|
| Weight | 1 Kg (2.2 Lbs) |
| Input AC | 100-240 VAC (+/-10%) ~50/60 Hz, 0.6A |
| Output DC | 24VDC – 1.04 Amp maximum |
| Maximum cycle rate | 600 cycles per minute |
| Air input requirements | 7 bar (100 psi) maximum |
| Air output | 1-7 bar (1-100 psi) dependent on user setting |
| Ambient operating temperature | 5°C to 45°C (41°F-113°F) |
| Humidity | 85% RH at 30°C non-condensing |
| Maximum altitude | 2000 meters (6562 feet) |
| Approvals | CE, CSA; RoHS, WEEE & China RoHS compliant |
| Cycle initiate | Foot Pedal, Finger Switch |
Do not exceed a maximum operating pressure of 100 psi (7.0 kg/cm2); the maximum air input pressure is 6.9 bar (100 psi).
No. All EFD disposable components are precision engineered for one-time use, and attempting to clean and re-use them will compromise dispensing accuracy and may increase the risk of personal injury.
Remove all electrical and mechanical connections, wipe the surface with a moist cloth and light detergent, and use only clean dry air and a regulated power supply; no other regular maintenance is required.
Do not use halogenated hydrocarbon solvents in a pressurized system that contains aluminum components, as under pressure these solvents can react with aluminum and explode. Contact your EFD representative for compatible components if you must use them.