Nordson EFD 725HF High Flow Series Dispense Valves Installation Guide

Installation guide for the Nordson EFD 725HF High Flow Series Dispense Valves, covering setup, operation, and specifications.


Nordson EFD 725HF High Flow Series Dispense Valves Installation Guide - cover page
Brand
Nordson EFD
Category
Industrial Robot
Document type
Installation Guide
Language
English
Pages
4
File format
PDF
File size
575 KB
Published
28 October, 2026
Updated
28 October, 2026
MD5 checksum
1DC929B788B4220A9563C55AC99F3507

About this manual

This document serves as an installation guide for the Nordson EFD 725HF High Flow Series Dispense Valves. It details the steps for connecting fluid and air lines, installing nozzles, and setting reservoir pressure. The guide explains that the valve operates with a unique design providing clean fluid cutoff and pullback for precise application at high cycle rates.

What's inside

  • Introduction
  • Installation Steps
  • How the Valve Operates
  • ValveMate Concept
  • Specifications

Specifications

General Size90.2 mm length x 31.1 mm diameter (3.55" x 1.22")
Valve seal/diaphragm materialFDA-approved UHMW* polymer
Air pressure required4.8 to 6.2 bar (70 to 90 psi)
Maximum fluid pressure7.0 bar (100 psi)
Maximum operating temperature43° C (110° F)
725HF-SS Weight295 grams (10.4 oz)
725HF-A Weight181 grams (6.4 oz)

Frequently asked questions

What is the primary control of deposit size?

The primary control of deposit size is the valve open time.

What controller is recommended for the 725HF valve?

Nordson EFD recommends using the ValveMate 8000 controller for all automatic, semi-automatic and benchtop applications.

How does the valve operate?

Input air pressure forces the internal piston to move down, causing the diaphragm seal to deflect and the sealing head to open and permit fluid flow.

Download PDF (575 KB)