Installation guide for the Nordson EFD 725HF High Flow Series Dispense Valves, covering setup, operation, and specifications.
This document serves as an installation guide for the Nordson EFD 725HF High Flow Series Dispense Valves. It details the steps for connecting fluid and air lines, installing nozzles, and setting reservoir pressure. The guide explains that the valve operates with a unique design providing clean fluid cutoff and pullback for precise application at high cycle rates.
| General Size | 90.2 mm length x 31.1 mm diameter (3.55" x 1.22") |
|---|---|
| Valve seal/diaphragm material | FDA-approved UHMW* polymer |
| Air pressure required | 4.8 to 6.2 bar (70 to 90 psi) |
| Maximum fluid pressure | 7.0 bar (100 psi) |
| Maximum operating temperature | 43° C (110° F) |
| 725HF-SS Weight | 295 grams (10.4 oz) |
| 725HF-A Weight | 181 grams (6.4 oz) |
The primary control of deposit size is the valve open time.
Nordson EFD recommends using the ValveMate 8000 controller for all automatic, semi-automatic and benchtop applications.
Input air pressure forces the internal piston to move down, causing the diaphragm seal to deflect and the sealing head to open and permit fluid flow.