Operating manual for the Matrix Elektronik LDD-301-DI4-OP-S001 photoelectric distance sensor for Ex zones (0), 1, 2: technical data, wiring, safety notes.
This is the original operating manual for the LDD-301-DI4-OP-S001 photoelectric distance sensor manufactured by Matrix Elektronik AG. The sensor measures distances using the time-of-flight principle and is IECEx and ATEX certificated for use in Ex zones (0), 1 and 2. Measurement results are available in parallel at a PNP analog current output of 4 mA to 20 mA and an RS-485 serial interface.
The manual gives the technical data, the intended use, installation prescriptions for hazardous locations, the electrical connection assignment, safety regulations for class 2 laser devices, and notes on maintenance and disposal. It also contains the EC-/EU declaration of conformity with the ATEX and IECEx certification details, and a dimension drawing.
| Measuring method | Time-of-flight measuring |
|---|---|
| Measurement range, analog output | 0.05 m to 1.5 m |
| Measurement range, serial interface | 50 mm to 30 m |
| Supply voltage | 24 VDC ±10% |
| Maximum permissible voltage Um | 30 VDC |
| Current consumption | 70 mA |
| Maximum power dissipation | 2.4 W |
| Light source | Laser Class 2, <=1 mW, wavelength 620 nm to 690 nm |
| Response time | Minimum 0.25 s, maximum 4.5 s |
| Analog current output | PNP, 4 mA to 20 mA, short circuit protected, range 50 mm to 1500 mm |
| Serial interface format | RS-485, 9600 baud, 8 data bits, 1 stop bit, no parity, no handshaking |
| Housing | M42, stainless steel 1.4404 |
| Enclosure rating | IP67 according to EN 60529 |
| Ambient operating temperature range | -10 °C to +35 °C |
| Storage temperature range | -20 °C to +70 °C |
| Connection cable | 5 m, PUR jacket, 6+PE x 0.5 mm2, shielded, non-halogen |
| Ex protection, gas | II 2(1)G Ex d [op is Ga] IIA T3 Gb |
The analog output covers 0.05 m to 1.5 m, while the RS-485 serial interface covers 50 mm to 30 m.
It is allowed to be installed and operated within Ex zones 1 and 2, and the limited optical radiation can operate into zone 0 through a viewing glass.
It indicates an error: no valid measurement could be achieved. A current of 20.5 mA means no object could be detected within range.
The measurement process is started by applying +24 VDC at the START input and stops when the START input is connected to 0 V.
Disable the laser when no measurement is being made by applying 0 V to the START input, and do not exceed a housing temperature of +35 °C.