Matrix Elektronik LDD-301-DI4-OP-S001 Photoelectric Distance Sensor Operating Manual

Operating manual for the Matrix Elektronik LDD-301-DI4-OP-S001 photoelectric distance sensor for Ex zones (0), 1, 2: technical data, wiring, safety notes.


Matrix Elektronik LDD-301-DI4-OP-S001 Photoelectric Distance Sensor Operating Manual - cover page
Brand
Matrix Elektronik
Category
sensor
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
41 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
2B781F7F0A49AB47330F5F57884AB1E2

About this manual

This is the original operating manual for the LDD-301-DI4-OP-S001 photoelectric distance sensor manufactured by Matrix Elektronik AG. The sensor measures distances using the time-of-flight principle and is IECEx and ATEX certificated for use in Ex zones (0), 1 and 2. Measurement results are available in parallel at a PNP analog current output of 4 mA to 20 mA and an RS-485 serial interface.

The manual gives the technical data, the intended use, installation prescriptions for hazardous locations, the electrical connection assignment, safety regulations for class 2 laser devices, and notes on maintenance and disposal. It also contains the EC-/EU declaration of conformity with the ATEX and IECEx certification details, and a dimension drawing.

What's inside

  • Technical data
  • Intended use
  • Function
  • Analog current output
  • Serial interface
  • START input
  • Electrical connection
  • Installation prescriptions for hazardous locations
  • Safety regulations for laser devices class 2
  • Maintenance and durability

Specifications

Measuring methodTime-of-flight measuring
Measurement range, analog output0.05 m to 1.5 m
Measurement range, serial interface50 mm to 30 m
Supply voltage24 VDC ±10%
Maximum permissible voltage Um30 VDC
Current consumption70 mA
Maximum power dissipation2.4 W
Light sourceLaser Class 2, <=1 mW, wavelength 620 nm to 690 nm
Response timeMinimum 0.25 s, maximum 4.5 s
Analog current outputPNP, 4 mA to 20 mA, short circuit protected, range 50 mm to 1500 mm
Serial interface formatRS-485, 9600 baud, 8 data bits, 1 stop bit, no parity, no handshaking
HousingM42, stainless steel 1.4404
Enclosure ratingIP67 according to EN 60529
Ambient operating temperature range-10 °C to +35 °C
Storage temperature range-20 °C to +70 °C
Connection cable5 m, PUR jacket, 6+PE x 0.5 mm2, shielded, non-halogen
Ex protection, gasII 2(1)G Ex d [op is Ga] IIA T3 Gb

Frequently asked questions

What is the measurement range of the LDD-301-DI4-OP-S001?

The analog output covers 0.05 m to 1.5 m, while the RS-485 serial interface covers 50 mm to 30 m.

In which Ex zones can the sensor be installed and operated?

It is allowed to be installed and operated within Ex zones 1 and 2, and the limited optical radiation can operate into zone 0 through a viewing glass.

What does a 3.5 mA analog output current mean?

It indicates an error: no valid measurement could be achieved. A current of 20.5 mA means no object could be detected within range.

How is a measurement started and stopped?

The measurement process is started by applying +24 VDC at the START input and stops when the START input is connected to 0 V.

How can the lifetime of the laser be extended?

Disable the laser when no measurement is being made by applying 0 V to the START input, and do not exceed a housing temperature of +35 °C.

Download PDF (41 KB)

More Matrix Elektronik Manuals


View all Matrix Elektronik manuals →