Linear Technology's RS232 Quick Guide summarizes TIA/EIA-232-F pinouts, DB25/DB9 connectors, cable wiring, data rate and cable length limits.
The RS232 Quick Guide from Linear Technology summarizes the TIA/EIA-232-F standard. It describes RS232 as a single-ended, point-to-point modem interface that conveys data over a simple unterminated multiconductor cable; the guide notes that later renderings removed unneeded signals to expand its use as a general purpose serial interface at data rates up to 1MB.
The guide provides a DB25/DB9 signal pinout, connector and cable wiring for straight-through, null modem and AT-to-25-pin adapter setups, and relative signal timing for communications. Its specification table lists a 50-foot maximum cable length, 20kB/s maximum data rate, ±25V driver output and receiver input limits, and 3k to 7k termination.
| Mode of Operation | Single-ended |
|---|---|
| Drivers and Receivers per Line | 1 driver, 1 receiver |
| Maximum Cable Length | 50 feet* |
| Maximum Data Rate | 20kB/s |
| Maximum Voltage Applied to Driver Output | ±25V |
| Driver Output Signal | Minimum loaded ±5V; maximum unloaded ±15V |
| Termination | 3k < to 7k< |
| Receiver Input Sensitivity | ±3V |
The guide lists a maximum cable length of 50 feet, with a footnote for 2500pF cable capacitance at data rates less than 20k baud.
The specification table lists a maximum data rate of 20kB/s, and the guide says later renderings expanded use to data rates up to 1MB.
One driver and one receiver are allowed on one line.
The guide lists ±25V as the maximum voltage applied to the driver output.