Operating instructions for Leybold AR 4-8, AR 16-25 and AR 40-65 exhaust filters with lubricant feedback, covering installation, operation and maintenance.
The Leybold AR exhaust filter with lubricant feedback is supplied for the AR 4-8, AR 16-25 and AR 40-65 models. It attaches to the exhaust adapter of a TRIVAC B/BCS pump and traps oil mist and aerosols in the filter element.
These operating instructions cover design and function, technical data, supplied equipment, installation, oil change, filter element changes and Leybold service. They also state that waste oil must be disposed of through approved waste disposal arrangements.
| Models | AR 4-8, AR 16-25, AR 40-65 |
|---|---|
| Connection flange | DN 16 KF, 25 KF, 40 KF |
| Weight | 3.1 kg, 4.7 kg, 8.5 kg |
| Attached to | TRIVAC B/BCS pump exhaust adapter |
| Excess pressure valve limit | approx. 1.5 bar; 22 psig |
| Cat.-No. AR | 189 20, 189 21, 189 22 |
| Replacement filter element | FE 189 71, FE 189 72, FE 189 73 (2x) |
| Scope of supply | Lubricant feedback, intermediate flange, seal rings, connection lines, hollow-core screws, longer fastening screws |
| Mineral oil examples | N62; HE-200 in the USA |
| PFPE examples | NC 1/14 or HE-1600 in USA |
It is attached to the exhaust adapter of the respective TRIVAC B/BCS pump.
When the oil level exceeds a set point, the built-in float valve opens the fluid suction port and returns oil to the pump circulation.
It should not be used when pumping condensable vapours because condensates can back-stream into the pump and impair the lubricant.
The built-in excess pressure valve opens, allowing oil mist to escape directly into open air.